Observer Effect and Measurement Bias in Performance Analysis ; CU-CS-1042-08

نویسندگان

  • Todd Mytkowicz
  • Peter Sweeney
  • Matthias Hauswirth
  • Amer Diwan
  • Peter F. Sweeney
چکیده

To evaluate an innovation in computer systems, performance analysts measure execution time or other metrics using one or more standard workloads. The performance analyst may carefully minimize the amount of measurement instrumentation, control the environment in which measurement takes place, and repeat each measurement multiple times. Finally, the performance analyst may use statistical techniques to characterize the data. Unfortunately, even with such a responsible approach, the collected data may be misleading. This paper shows how easy it is to produce poor (and thus misleading) data for computer systems due to observer effect and measurement bias. Observer effect occurs if data collection perturbs the behavior of the system. Measurement bias occurs when a particular environment in which the measurement takes place favors some configurations over others. This paper demonstrates that observer effect and measurement bias have significant impact on performance and can lead to incorrect conclusions. These effects are large enough to easily mislead a performance analyst. Nevertheless, in our literature survey of recent PACT, CGO, and PLDI papers we found that papers rarely acknowledged or used reliable techniques to avoid observer effect or measurement bias. We describe and demonstrate techniques that help a performance analyst identify situations when they have poor quality data. These techniques are based on causality analysis and statistics which natural and social sciences routinely use to avoid the observer effect and measurement bias.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Observer Effect and Measurement Bias in Performance Analysis

To evaluate an innovation in computer systems, performance analysts measure execution time or other metrics using one or more standard workloads. The performance analyst may carefully minimize the amount of measurement instrumentation, control the environment in which measurement takes place, and repeat each measurement multiple times. Finally, the performance analyst may use statistical techni...

متن کامل

Performance Analysis Of Mono-bit Digital Instantaneous Frequency Measurement (Difm) Device

Instantaneous Frequency Measurement (IFM) devices are the essential parts of anyESM, ELINT, and RWR receiver. Analog IFMs have been used for several decades. However, thesedevices are bulky, complex and expensive. Nowadays, there is a great interest in developing a wideband, high dynamic range, and accurate Digital IFMs. One Digital IFM that has suitably reached allthese requirements is mono-bi...

متن کامل

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

We have it easy , but do we have it right ? Todd

We show two severe problems with the state-of-the-art in empirical computer system performance evaluation, observer effect and measurement context bias, and we outline the path toward a solution.

متن کامل

Adsorption of Pyrazolone[HPMSP1,Calix[4]-arene, Cu(II) and Cs on Carbon Nanotube

The adsorption of pyrazolone(HPMSP), Calix[4]-arene,Cu and Cs, on carbon nanotube(CNT) atroom temperature has been investigated using spectroscopy.Uv spectroscopy indicated that pyrazolone molecules adsorbed on carbon nanotube at roomtemperature in compared calix[4]- arene molecules adsorbed approximately same.The amount ofpyrazolone(HPMSP) adsorb 3.8. le mol/g and amount calix[4]-arene adsorbe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015