BACKGROUND Reliable serum creatinine measurements in glomerular filtration rate (GFR) estimation are critical to ongoing global public health efforts to increase the diagnosis and treatment of chronic kidney disease (CKD). We present an overview of the commonly used methods for the determination of serum creatinine, method limitations, and method performance in conjunction with the development of analytical performance criteria. Available resources for standardization of serum creatinine measurement are discussed, and recommendations for measurement improvement are given. METHODS The National Kidney Disease Education Program (NKDEP) Laboratory Working Group reviewed problems related to serum creatinine measurement for estimating GFR and prepared recommendations to standardize and improve creatinine measurement. RESULTS The NKDEP Laboratory Working Group, in collaboration with international professional organizations, has developed a plan that enables standardization and improved accuracy (trueness) of serum creatinine measurements in clinical laboratories worldwide that includes the use of the estimating equation for GFR based on serum creatinine concentration that was developed from the Modification of Diet in Renal Disease (MDRD) study. CONCLUSIONS The current variability in serum creatinine measurements renders all estimating equations for GFR, including the MDRD Study equation, less accurate in the normal and slightly increased range of serum creatinine concentrations [<133 micromol/L (1.5 mg/dL)], which is the relevant range for detecting CKD [<60 mL.min(-1).(1.73 m2)(-1)]. Many automated routine methods for serum creatinine measurement meet or exceed the required precision; therefore, reduction of analytical bias in creatinine assays is needed. Standardization of calibration does not correct for analytical interferences (nonspecificity bias). The bias and nonspecificity problems associated with some of the routine methods must be addressed.
منابع مشابه
Acute kidney injury: time to shift from creatinine to the estimated glomerular filtration rate?
Acute kidney injury (AKI) is a complex disorder for which currently there is no accepted definition. Although several groups are working on developing and validating biomarkers of kidney injury and the glomerular filtration rate (GFR), the proposed diagnostic criteria from the Acute Kidney Injury Network are based on an absolute increase in serum creatinine ≥0.3 mg/dl (≥26.4 μmol/l), a percenta...
متن کاملThe role of laboratory testing in detection and classification of chronic kidney disease: national recommendations
Chronic kidney disease (CKD) is a common clinical condition with significant adverse consequences for the patient and it is recognized as a significant public health problem. The role of laboratory medicine in diagnosis and management of CKD is of great importance: the diagnosis and staging are based on estimation of glomerular filtration rate (eGFR) and assessment of albuminuria (or proteinuri...
متن کاملPrevalence of estimated GFR reporting among US clinical laboratories.
BACKGROUND Routine laboratory reporting of estimated glomerular filtration rate (eGFR) may help clinicians detect kidney disease. The current national prevalence of eGFR reporting in clinical laboratories is unknown; thus, the extent of the situation of laboratories not routinely reporting eGFR with serum creatinine results is not quantified. DESIGN Observational analysis. SETTING National ...
متن کاملChronic kidney disease and automatic reporting of estimated glomerular filtration rate: revised recommendations.
Since publication of the Australasian Creatinine Consensus Working Group's position statement in 2005, most Australasian laboratories now automatically report an estimated glomerular filtration rate (eGFR) (based on the Modification of Diet in Renal Disease [MDRD] formula) with results of serum creatinine tests in adults. Anecdotal evidence suggests that automatic reporting of eGFR helps to ide...
متن کاملA reference system for urinary albumin: current status.
BACKGROUND Increased urinary excretion of albumin reflects kidney damage and is a recognized risk factor for progression of renal and cardiovascular disease. Considerable inter-method differences have been reported for both albumin and creatinine measurement results, and therefore the albumin-to-creatinine ratio. Measurement accuracy is unknown and there are no independent reference measurement...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 52 1 شماره
صفحات -
تاریخ انتشار 2006