Aortic length measurements for pulse wave velocity calculation: manual 2D vs automated 3D centreline extraction
نویسندگان
چکیده
BACKGROUND Pulse wave velocity (PWV) is a biomarker for the intrinsic stiffness of the aortic wall, and has been shown to be predictive for cardiovascular events. It can be assessed using cardiovascular magnetic resonance (CMR) from the delay between phase-contrast flow waveforms at two or more locations in the aorta, and the distance on CMR images between those locations. This study aimed to investigate the impact of different distance measurement methods on PWV. We present and evaluate an algorithm for automated centreline tracking in 3D images, and compare PWV calculations using distances derived from 3D images to those obtained from a conventional 2D oblique-sagittal image of the aorta. METHODS We included 35 patients from a twin cohort, and 20 post-coarctation repair patients. Phase-contrast flow was acquired in the ascending, descending and diaphragmatic aorta. A 3D centreline tracking algorithm is presented and evaluated on a subset of 30 subjects, on three CMR sequences: balanced steady-state free precession (SSFP), black-blood double inversion recovery turbo spin echo, and contrast-enhanced CMR angiography. Aortic lengths are subsequently compared between measurements from a 2D oblique-sagittal plane, and a 3D geometry. RESULTS The error in length of automated 3D centreline tracking compared with manual annotations ranged from 2.4 [1.8-4.3] mm (mean [IQR], black-blood) to 6.4 [4.7-8.9] mm (SSFP). The impact on PWV was below 0.5m/s (<5%). Differences between 2D and 3D centreline length were significant for the majority of our experiments (p < 0.05). Individual differences in PWV were larger than 0.5m/s in 15% of all cases (thoracic aorta) and 37% when studying the aortic arch only. Finally, the difference between end-diastolic and end-systolic 2D centreline lengths was statistically significant (p < 0.01), but resulted in small differences in PWV (0.08 [0.04 - 0.10]m/s). CONCLUSIONS Automatic aortic centreline tracking in three commonly used CMR sequences is possible with good accuracy. The 3D length obtained from such sequences can differ considerably from lengths obtained from a 2D oblique-sagittal plane, depending on aortic curvature, adequate planning of the oblique-sagittal plane, and patient motion between acquisitions. For accurate PWV measurements we recommend using 3D centrelines.
منابع مشابه
Robust segmentation methods with an application to aortic pulse wave velocity calculation
Aortic stiffness has proven to be an important diagnostic and prognostic factor of many cardiovascular diseases, as well as an estimate of overall cardiovascular health. Pulse wave velocity (PWV) represents a good measure of the aortic stiffness, while the aortic distensibility is used as an aortic elasticity index. Obtaining the PWV and the aortic distensibility from magnetic resonance imaging...
متن کاملColon Centreline Calculation for CT Colonography using Optimised 3D Topological Thinning
CT colonography is an emerging technique for colorectal cancer screening. Using this technique virtual reality models of the human colon are generated from an abdominal CT study of a suitably prepared patient. Manual navigation through these models is a slow and tedious process. It is possible to automate navigation by calculating the centreline of the human colon. There are numerous well docum...
متن کاملMeasurement of aortic pulse wave velocity in CMR: comparison of transit time estimators
Background CMR is increasingly used for measuring aortic arch PWV (arch-PWV) by using accurate aortic length and transit time between flow waves. If robust aortic length measurement is an obvious strength of CMR thanks to many 3D imaging approaches available, Δt measurement remains a major challenge. Consequently, different methods have been previously described to estimate the Δt using CMR, bu...
متن کاملBlood Vessels Distal Shift of Arterial Pressure Wave Reflection Sites With Aging
An early return of reflected waves, the backward propagation of the arterial pressure wave from the periphery to the heart, is associated with the augmentation of central pulse pressure and cardiovascular risks. The locations of arterial pressure wave reflection, along with arterial stiffening, have a major influence on the timing of the reflected wave. To determine the influence of aging on th...
متن کاملAutomated quantitative 3-dimensional modeling of the aortic valve and root by 3-dimensional transesophageal echocardiography in normals, aortic regurgitation, and aortic stenosis: comparison to computed tomography in normals and clinical implications.
BACKGROUND We tested the ability of a novel automated 3-dimensional (3D) algorithm to model and quantify the aortic root from 3D transesophageal echocardiography (TEE) and computed tomographic (CT) data. METHODS AND RESULTS We compared the quantitative parameters obtained by automated modeling from 3D TEE (n=20) and CT data (n=20) to those made by 2D TEE and targeted 2D from 3D TEE and CT in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 19 شماره
صفحات -
تاریخ انتشار 2017