The effect of section thickness on MR lesion detection and quantification in multiple sclerosis.

نویسندگان

  • P D Molyneux
  • N Tubridy
  • G J Parker
  • G J Barker
  • D G MacManus
  • P S Tofts
  • I F Moseley
  • D H Miller
چکیده

BACKGROUND AND PURPOSE The purpose of our study was to investigate the effect of section thickness on MR detection of brain lesion volume and measurement precision in patients with multiple sclerosis (MS). METHODS Eight subjects with known MS were studied on a 1.5-T MR system. We used a 3D fast fluid-attenuated inversion-recovery sequence to obtain contiguous axial brain images at section thicknesses of 5 mm, 3 mm, and 1 mm. Two sets of images were acquired at each section thickness during two sessions, between which the patient was removed from the scanner. Lesion volumes were measured at each section thickness using a semiautomated local thresholding technique. RESULTS We found that progressive reduction in section thickness led to detection of smaller lesions, resulting in a significant (8%) increase in lesion volume on MR images as section thickness was reduced from 5 mm to 3 mm. However, despite a further increase in lesion detection at a section thickness of 1 mm, this did not result in an increase in total lesion volume. This finding indicates that the relationship between section thickness and lesion volume on MR images is not linear. Scan-rescan reproducibility was improved by reducing section thickness, at the cost of increased analysis time. CONCLUSION This study shows that acquisition of very thin sections increases the sensitivity and precision of MS lesion measurement. Serial studies assessing lesion changes over time are needed to define the impact of this increase on sample size requirements for MS treatment trials.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of variation in slice thickness and interslice gap on MR lesion detection.

Lesion detection by MR imaging depends on the contrast-to-noise ratio of the voxels containing the lesion relative to those containing the background. When the lesion voxels are less than completely filled, the inherent contrast between lesion and background is modified by the filling factor. Lesion detection thus depends on lesion size, slice thickness, lesion position relative to slice, thick...

متن کامل

Automated Detection of Multiple Sclerosis Lesions Using Texture-based Features and a Hybrid Classifier

Background: Multiple Sclerosis (MS) is the most frequent non-traumatic neurological disease capable of causing disability in young adults. Detection of MS lesions with magnetic resonance imaging (MRI) is the most common technique. However, manual interpretation of vast amounts of data is often tedious and error-prone. Furthermore, changes in lesions are often subtle and extremely unrepresentati...

متن کامل

Fast spin-echo and fast fluid-attenuated inversion-recovery versus conventional spin-echo sequences for MR quantification of multiple sclerosis lesions.

PURPOSE To compare fast spin-echo (FSE) and fast fluid-attenuated inversion recovery (FLAIR) sequences with conventional spin-echo (CSE) MR imaging in the quantification of the number and volume of multiple sclerosis lesions. METHODS In 30 patients with relapsing-remitting multiple sclerosis, we calculated the total number and volume of lesions detected with each of the three sequences using ...

متن کامل

Quantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging

Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...

متن کامل

The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques

Background and objective: Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don’t have MS plaques or MRI images are not enough optimized enough in order to show MS plaques? The aim of the current study is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 19 9  شماره 

صفحات  -

تاریخ انتشار 1998