MR imaging of optic neuropathy with extended echo-train acquisition fluid-attenuated inversion recovery.

نویسندگان

  • A H Aiken
  • P Mukherjee
  • A J Green
  • C M Glastonbury
چکیده

BACKGROUND AND PURPOSE XETA, also known as Cube, is a relatively new 3D FSE sequence that can be used to perform whole-brain FLAIR T2-weighted imaging at isotropic high spatial resolution. This high-resolution volumetric imaging, coupled with both fat and fluid suppression, permits ideal evaluation of optic nerve anatomy and signal intensity; therefore, we hypothesized that XETA FLAIR would be useful for the detection of T2 signal-intensity abnormality in the optic nerve. Our purpose was to evaluate the sensitivity of XETA FLAIR for this abnormality and to compare it with the coronal FSE T2 FS. MATERIALS AND METHODS After obtaining approval of the institutional review board, 2 CAQ neuroradiologists retrospectively reviewed all patients with a clinical diagnosis of optic neuropathy who had undergone XETA FLAIR and standard orbital imaging from September 2006 to February 2009. Fifteen patients met these criteria and underwent the following sequences: XETA FLAIR, coronal FSE T2 FS, and T1-weighted postgadolinium sequences with FS. RESULTS Signal-intensity abnormality was identified on the correct side of the patient's vision loss in all 15 patients on XETA but in only 11/15 patients on the coronal FSE T2-weighted imaging. Reviewer 1 perceived the signal-intensity abnormality better on the XETA versus T2-weighted imaging in 10/15 patients, and reviewer 2, in 9/15 patients. Neither reviewer visualized any of the imaging better by using the conventional coronal FSE T2 FS sequence. CONCLUSIONS XETA FLAIR was more sensitive than coronal FSE T2 FS for identifying abnormal signal intensity within the optic nerves in patients with optic neuropathy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast inversion-recovery MR: the effect of hybrid RARE readout on the null points of fat and cerebrospinal fluid.

PURPOSE To evaluate the effect of the hybrid RARE (rapid acquisition with relaxation enhancement) readout, commonly coupled to inversion-recovery pulse sequences, on the null inversiton time (TI) of fluid and fat using both phantoms and human volunteers. METHODS Two phantoms, simulating fat (phantom A) and cerebrospinal fluid (phantom B), respectively, were imaged using a fast inversion-recov...

متن کامل

T2 relaxation measurements in X-linked adrenoleukodystrophy performed using dual-echo fast fluid-attenuated inversion recovery MR imaging.

SUMMARY The purpose of this study was to determine whether dual-echo fast fluid-attenuated inversion recovery MR imaging and corresponding T2 brain maps can show different zones in the affected white matter of patients with cerebral X-linked adrenoleukodystrophy. Ten male patients with cerebral X-linked adrenoleukodystrophy underwent imaging performed using dual-echo fast fluid-attenuated inver...

متن کامل

Combined fat- and water-suppressed MR imaging of orbital tumors.

BACKGROUND AND PURPOSE The use of a high-resolution T2-weighted MR sequence, which suppresses signal from both fat and water, has been shown to be highly effective for depicting areas of inflammatory damage within the optic nerve. The ability of this sequence to show neoplastic and inflammatory orbital lesions, which may mimic neuritis, is unknown. This study was designed to examine the charact...

متن کامل

MR of the spine with a fast T1-weighted fluid-attenuated inversion recovery sequence.

PURPOSE To optimize a T1-weighted fast fluid-attenuated inversion recovery (FLAIR) sequence using computer-simulated data and to study its clinical utility for imaging the spine. METHODS Relative signal intensities and contrast of relevant normal and pathologic tissues in the spine were computed using an inversion recovery equation modified to account for a hybrid RARE (rapid acquisition with...

متن کامل

A streamlined acquisition for mapping baseline brain oxygenation using quantitative BOLD

Quantitative BOLD (qBOLD) is a non-invasive MR technique capable of producing quantitative measurements of the haemodynamic and metabolic properties of the brain. Here we propose a refinement of the qBOLD methodology, dubbed streamlined-qBOLD, in order to provide a clinically feasible method for mapping baseline brain oxygenation. In streamlined-qBOLD confounding signal contributions are minimi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 32 2  شماره 

صفحات  -