Reproducibility of the interpretation of pelvic x-ray 3 months after hysteroscopic sterilization with Essure.

نویسندگان

  • Sebastiaan Veersema
  • Ben W J Mol
  • Hans A M Brölmann
چکیده

OBJECTIVE To estimate the diagnostic accuracy and the interobserver reproducibility of pelvic x-rays in the diagnosis of successful bilateral sterilization with Essure after a 3-month follow-up period. DESIGN Interobserver study. SETTING Outpatient department of obstetrics and gynecology in a Dutch teaching hospital. PATIENT(S) Patients with successful bilateral Essure placement. INTERVENTION(S) Hysteroscopic sterilization with Essure and pelvic x-ray and hysterosalpingography after a 3-month follow-up period. MAIN OUTCOME MEASURE(S) Six observers evaluations of 47 pelvic x-rays from 47 patients 3 months after a technical successful bilateral placement of microinserts to estimate the reliability of the sterilization. Diagnostic accuracy of pelvic x-ray per observer in detecting incorrectly positioned microinserts was expressed in terms of sensitivity and specificity, with hysterosalpingography as the reference strategy. Reproducibility of the interpretation of the pelvic x-ray was expressed as kappa-values. RESULT(S) The sensitivity and specificity for x-rays read by gynecologists was 0.67 (95% confidence interval [CI], 0.29-0.96) and 0.79 (95% CI, 0.58-1.00) and for radiologists 1.0 and 0.5 (95% CI, 0.36-0.64). The interobserver agreement in reliability of pelvic x-ray of hysteroscopic sterilization assessment with Essure ranged from slight (kappa-value=0.09) for gynecologists to moderate (kappa-value=0.52) for radiologists. CONCLUSION(S) Test characteristics of pelvic x-ray as the imaging technique to assess the position of the Essure microinserts and tubal patency were poor, as was the reproducibility, particularly if gynecologists performed the evaluation. We do not recommend the use of pelvic x-ray for the assessment of the positioning of microinserts after hysteroscopic sterilization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Follow-up of successful bilateral placement of Essure microinserts with ultrasound.

OBJECTIVE To evaluate the reliability of pelvic X-ray and transvaginal ultrasound to localize Essure microinserts (Conceptus, San Carlos, California) after successful placement in both fallopian tubes 3 months after placement. DESIGN Prospective, observational study. SETTING Gynecology departments at two teaching hospitals. PATIENT(S) One hundred eighty-two patients who underwent hysteros...

متن کامل

Discordant relationship between Essure microinsert position and tubal occlusion.

Hysteroscopic sterilisation with Essure requires confirmation of tubal occlusion by hysterosalpingogram or microinsert position by transvaginal sonography 3 months after placement before women can rely on the method for pregnancy prevention. A 39-year-old woman underwent hysteroscopic sterilisation via Essure, with successful bilateral tubal occlusion documented on hysterosalpingogram. She had ...

متن کامل

Essure Surgical Removal and Subsequent Resolution of Chronic Pelvic Pain: A Case Report and Review of the Literature

Background. Hysteroscopic tubal sterilization (Essure) is a minimally invasive option for permanent contraception with high reported rates of patient satisfaction. A small percentage of these women subsequently choose to have the tubal inserts removed due to regret or perceived side effects such as late-onset pelvic pain secondary to placement of the Essure device. Case. A twenty-nine-year-old ...

متن کامل

Venous intravasation: a potential pitfall of confirmatory hysterosalpingogram following essure hysteroscopic sterilization.

Indications for hysterosalpingography (HSG) include evaluation of infertility, spontaneous abortions, postoperative evaluation of tubal ligation, pre-myomectomy evaluation, and more recently, evaluation of tubal occlusion after placement of the Essure Permanent Birth Control System. Here we report a case of venous intravasation during a routine post-Essure HSG, a phenomenon in which contrast tr...

متن کامل

Surgical excision of Essure® devices with ESHRE Class IIb uterine malformation: sequential hysteroscopic-laparoscopic approach to the septate uterus

OBJECTIVE While contraindications to Essure® placement have been provided by the manufacturer, there is no consensus on how best to remove these contraceptive devices. Here, we describe a non-hysterectomy removal of Essure® for a patient with a septate uterus (ESHRE Class IIb uterine malformation). CLINICAL CASE A 35yr old G4 P2 presented for removal of Essure® implants after three years of g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Fertility and sterility

دوره 94 4  شماره 

صفحات  -

تاریخ انتشار 2010