Keith R . Allen Derek Watson Liquid Chromatography of Glycated Hemobglobins with the Dalichi HA - 8110 Automated Analyzer

نویسندگان

  • Keith R. Allen
  • Derek Watson
چکیده

Our results show a good discrimination among the patient groups studied. Most thyrotoxic patients had TSH values below 0.2 milli-int. unitlL. Of the four patients whose values exceeded this, two were receiving anti-thyroid drugs, one was originally hypothyroid andovertreated, and the fourth was a previously thyrotoxic patient who had relapsed after withdrawal of drug therapy. All newly presenting thyrotoxic patients had values below 0.2 milli-int. uniL. This assay clearly distinguished hypothyroid patients from the euthyroid group, values for the latter being within the range 0.3 to 7 milli-int. units/L andthose for the hypothyroids exceeding 10 milli-int. units/L. Three patients initially diagnosed as having hypothyroidism fell into the thyrotoxic group as a result of overtreatment with thyroxin; two of these patients had TSH values below 0.2 milli-int. unit/L. The assay we currently use for serum TSH (Nuclear Medical Laboratories), although very satisfactory for the detection of hypothyroidism, cannot detect a TSH of less than 2 millimt. units/L and thus is unsuitable for the investigation of thyrotoxicosis. The IRMA, however, appears potentially useful as the initial screening test for thyroid disease. More work is required, in whichthis assay is used to measure TSH in patients being treated for thyrotoxicosis and in patients who have relapsed after withdrawal of drug therapy for this condition. For monitoring hypothyroidism the IRMA clearly identified two patients who were overtreated with thyroxin; this would not havebeen possible with a conventional radioimmunoassay for thyrotropin.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Semi-automated colorimetric method for measuring glycohemoglobin, with reduction of nitroblue tetrazolium, evaluated.

I evaluated a semi-automated method for measuring glycohemoglobin via reduction of nitroblue tetrazolium by acetone-extracted globin. The simultaneous measurement of glycated protein and total protein with the Roche Mira S analyzer showed good analytical precision (between-batch CV 3.5%-8.5%). Correlation of results (y) with those by a boronate affinity chromatography method (x) gave a regressi...

متن کامل

The validation of an automated liquid chromatography system for the diagnosis of thalassemias and hemoglobinopathies.

Accurate and precise hemoglobin separation and the quantitation of Hb A2 and Hb F are essential for the diagnosis of the thalassemias and hemoglobinopathies. Presented in this study is the validation of the the Hb A2 assay of the HbGold analyzer, a fully automated liquid chromatography system for hemoglobin separation and quantitation. Variability of Hb A2 quantitation was quite low; the CV's o...

متن کامل

Three assays for glycohemoglobin compared.

Using 123 specimens, we compared the concordance of three different methods for determining glycohemoglobin (GHb): the Diamat (Bio-Rad Laboratories), an automated analyzer measuring HbA1c by cation-exchange chromatography; an assay with the IMx analyzer (Abbott Laboratories), based on boronate affinity binding; and an HPLC method measuring HbA1c by cation-exchange chromatography on a PolyCAT A ...

متن کامل

Adaptation of latex-enhanced assay for percent glycohemoglobin to a Dade Dimension analyzer.

At present no method for glycohemoglobin (%HbA1c) is automated on a main-line analyzer to allow joint measurement with other indicators of diabetic control such as glucose and cholesterol. We describe an adaptation of a latex-enhanced competitive immunoassay for quantifying %HbA1c to the Dade International Dimension analyzer. After a manual hemolysis step, HbA1c and total hemoglobin (Hb) are de...

متن کامل

Non-separation assay for glycohemoglobin.

The determination of glycohemoglobin [HbA1c, HbA1, or total glycohemoglobin (GHb)] has become an established procedure in the management of diabetes mellitus. Here, we describe the development of a simple, fluorescence, non-separation assay for the percentage of GHb (%GHb). The fluorescence of an eosin-boronic acid derivative when it was mixed with hemolysates of unwashed erythrocytes was quenc...

متن کامل