Determination of Cadmium, Copper, Iron, Manganese, Lead and Zinc in Lichens and Botanic Samples by Electrothermal and Flame Atomic Absorption Spectrometry

نویسندگان

  • Orhan ACAR
  • Sümer ÖZVATAN
  • Murat İLİM
چکیده

Within the framework of the International Atomic Energy Agency (IAEA) Analytical Quality Control Service (AQCS) Chemistry Unit a research program was initiated for the identification of trace elements such as Cd, Cu, Fe, Mn, Pb and Zn in IAEA lichen-338 for a proficiency test (PT). This was to evaluate the possibility of using lichens as biomonitors of trace elements in atmospheric pollution. Pyrolysis and atomization temperatures, atomization and background profiles, detection limits and characteristic masses of analytes in lichen samples with Ni, Ni + Pd and Ni + Pd + tartaric acid (TA) modifier mixture, and without any modifiers were comprehensively investigated by electrothermal atomic absorption spectrometry (ETAAS). The detection limits and characteristic masses of analytes obtained were 0.06 μg L−1 and 2.04 pg for Cd, 1.26 μg L−1 and 18.4 pg for Pb, 0.66 μg L−1 and 6.4 pg for Cu, 0.16 μg L−1 and 1.42 pg for Mn in ETAAS with (Ni + Pd + TA), and 72.1 μg L−1 for Fe and 20.1 μg L−1 for Zn in flame atomic absorption spectrometry (FAAS). Cd, Cu, Pb and Mn in tomato leaves (1573a) from the National Institute of Standards and Technology (NIST) and hay powder (V-10) from IAEA certified reference materials (CRMs) and in lichen samples by ETAAS with Ni + Pd + TA, and Fe and Zn by FAAS were determined. The results obtained in CRMs were in good agreement with the certified values and the recoveries were about 100%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of lead and cadmium in water samples by cloud point extraction prior to flame atomic absorption spectrometry determination

Pb and Cd in water samples were determined by cloud point extraction (CPE) with sodiumdiethyldithiocarbamate (DDTC) as the chelating agent and octylphenoxypolyethanl (Triton X-114) asthe surfactant prior to flame atomic absorption spectrometry (FAAS) determination. The main factorsof affecting the extraction and detection processes were optimized. The preconcentration of 10 mL ofstandard soluti...

متن کامل

Extraction and Determination of Heavy Metals Using Silver Coated Magnetic Nanoparticles and Flame Atomic Absorption Spectrometry

A rapid, simple and sensitive magnetic solid phase extraction (MSPE) method was developed for the pre-concentration and determination of copper and cadmium ions. In this study, modified Fe3O4@Ag nanoparticles were synthesized and then ligand 2-isonicotinoyl hydrazine carbodithiolate (ITHCDT) was bonded to silver due to the formation of covalent bond of S-Ag. In this method, copper and cadmium i...

متن کامل

Use of masking agents in the determination of lead in tap water by flame atomic absorption spectrometry with flow injection pre-concentration.

The selectivity of immobilised 8-hydroxyquinoline for lead is shown to be improved by the use of masking agents during pre-concentration, prior to determination by flame atomic absorption spectrometry. Interference by iron, copper, aluminium and zinc is suppressed by including triethanolamine, thiourea, fluoride, acetylacetone or cyanide in the buffer as masking agents. Species such as iron or ...

متن کامل

Determination of Metal Contents in Edible Vegetable Oils Produced in Iran Using Microwave-assisted Acid Digestion

The concentration of heavy metals in vegetable oils is an important criterion for the assessment of oil qualities with regard to freshness, keeping properties, storage and their influence on human nutrition and health. Trace heavy metals in vegetable oils are known to have an effect on the rate of oil oxidation. In this work, the contents of lead (Pb), cadmium (Cd), nickel (Ni), manganese (Mn),...

متن کامل

Determination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop

The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005