How I do it: feasibility of a new ultrasound probe fixator to facilitate high quality stress echocardiography
نویسندگان
چکیده
BACKGROUND Stress echocardiography (SE) has recently regained momentum as an important diagnostic tool for the assessment of both ischemic and non-ischemic heart disease. Performing SE during physical exercise is challenging due to a suboptimal patient position and vigorous movements of the patient's chest. This hampers a stable ultrasound position and reduces the diagnostic performance of SE. A stable ultrasound probe position would facilitate producing high quality images during continuous measurements. With Probefix (Usono, Eindhoven, The Netherlands), a newly developed tool to fixate the ultrasound probe to the patient's chest, stabilization of the probe during physical exercise is possible. IMPLEMENTATION AND RESULTS The technique of SE with the Probefix and its' feasibility are evaluated in a small pilot study. Probefix fixates the ultrasound probe to the patient's chest, using two chest straps and a fixation device. The ultrasound probe position and angle may be altered with a relative high degree of freedom. We tested the Probefix for continuous echocardiographic imaging in 12 study subjects during supine and upright ergometer stress tests. One patient was unable to perform exercise and in two study subjects good quality images were not achieved. In the other patients (82%) a stable probe position was obtained, with subsequent good quality echocardiographic images during SE. CONCLUSION We have demonstrated the feasibility of the Probefix support during ergometer tests in supine and upright positions and conclude that this external fixator may facilitate continuous monitoring of cardiac function in a group of patients.
منابع مشابه
Feasibility of real-time three-dimensional stress echocardiography: pharmacological and semi-supine exercise
BACKGROUND Real time three dimensional (RT3D) echocardiography is an accurate and reproducible method for assessing left ventricular shape and function. AIM assess the feasibility and reproducibility of RT3D stress echocardiography (SE) (exercise and pharmacological) in the evaluation of left ventricular function compared to 2D. METHODS AND RESULTS One hundred eleven patients with known or ...
متن کاملNon-invasive estimation of cardiac wall stress by using tissue doppler-echocardiography ultrasound images: People with coronary artery stenosis
In this study, a method for non-invasive estimation of stress on the heart wall in the diastole phase is presented using ultrasound echocardiography and tissue Doppler imaging. The aim of this study was to evaluate the stress on the heart wall as a pre-diagnosis to identify people with coronary artery stenosis. 29 patients with stenosis of more than 70%, 30 patients with stenosis of 50 to 7...
متن کاملدرآمدی بر مبنای مکان یابی و طراحی بیمارستان ها
Background: The hospital is an important element in the new public health. The health in the populations requires access to the medical and hospital services as well as preventive care and a healthy environment. This study attempts to review the important factors to be considered in the hospital sites selected and design in the urban, regional and country levels. Finally, suggestions have exhib...
متن کاملDesign, Evaluation and Prototyping of a New Robotic Mechanism for Ultrasound Imaging
This paper presents a new robotic mechanism for ultrasound imaging. The device is placed on a patient's body by an operator, and an ultrasound expert controls the motions of the device to obtain ultrasound images. The paper focuses on the robotic mechanism that performs ultrasound imaging. The design of the mechanism is based on two approaches to produce center of motion for an ultrasound probe...
متن کاملEffect of face-to-face training and pamphlets in reducing anxiety in 7-25 years old clients referred to echocardiography
Introduction: Echocardiography is a diagnostic test in that ultrasound waves are used for producing images of the heart muscle and valves. Echocardiography provides a series of useful information about the heart and its function for treatment purpose. It is especially useful for assessing valvular heart disease. Although it has no known side effect, but similar to any other medical procedure, i...