Time-of-Flight 3-D Endoscopy

نویسندگان

  • Jochen Penne
  • Kurt Höller
  • Michael Stürmer
  • Thomas Schrauder
  • Armin Schneider
  • Rainer Engelbrecht
  • Hubertus Feußner
  • Bernhard Schmauss
  • Joachim Hornegger
چکیده

This paper describes the first accomplishment of the Time-of-Flight (ToF) measurement principle via endoscope optics. The applicability of the approach is verified by in-vitro experiments. Off-the-shelf ToF camera sensors enable the per-pixel, on-chip, real-time, marker-less acquisition of distance information. The transfer of the emerging ToF measurement technique to endoscope optics is the basis for a new generation of ToF rigid or flexible 3-D endoscopes. No modification of the endoscope optic itself is necessary as only an enhancement of illumination unit and image sensors is necessary. The major contribution of this paper is threefold: First, the accomplishment of the ToF measurement principle via endoscope optics; second, the development and validation of a complete calibration and post-processing routine; third, accomplishment of extensive in-vitro experiments. Currently, a depth measurement precision of 0.89 mm at 20 fps with 3072 3-D points is achieved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ToF/RGB Sensor Fusion for 3-D Endoscopy

Acquisition of 3-D anatomical structure in minimally invasive surgery is an important step towards intra-operative guidance. In this context, the rst prototype of a Time-of-Flight/RGB endoscope was engineered for simultaneous range and color data acquisition. Intrinsic and stereo camera calibration are essential to achieve an intuitive visualization of colored surfaces. Due to the early prototy...

متن کامل

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

ToF/RGB Sensor Fusion for Augmented 3D Endoscopy using a Fully Automatic Calibration Scheme

3-D Endoscopy is an evolving field of research and offers great benefits for minimally invasive procedures. Besides the pure topology, color texture is an inevitable feature to provide an optimal visualization. Therefore, in this paper, we propose a sensor fusion of a Time-of-Flight (ToF) and an RGB sensor. This requires an intrinsic and extrinsic calibration of both cameras. In particular, the...

متن کامل

Spatial orientation in translumenal surgery.

"Natural Orifice Translumenal Endoscopic Surgery" (NOTES) is assumed to offer significant benefits to patients, such as reduced trauma as well as reduced collateral damage. But the potential advantages of this new technology can only be achieved through safe and standardized operation methods. Several barriers, which have been identified during clinical practice in flexible intra-abdominal endo...

متن کامل

ToF Meets RGB: Novel Multi-Sensor Super-Resolution for Hybrid 3-D Endoscopy

3-D endoscopy is an evolving field of research with the intention to improve safety and efficiency of minimally invasive surgeries. Time-of-Flight (ToF) imaging allows to acquire range data in real-time and has been engineered into a 3-D endoscope in combination with an RGB sensor (640x480px) as a hybrid imaging system, recently. However, the ToF sensor suffers from a low spatial resolution (64...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention

دوره 12 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2009