Vibration measurements of high-heat-load monochromators for DESY PETRA III extension
نویسندگان
چکیده
The requirement for vibrational stability of beamline optics continues to evolve rapidly to comply with the demands created by the improved brilliance of the third-generation low-emittance storage rings around the world. The challenge is to quantify the performance of the instrument before it is installed at the beamline. In this article, measurement techniques are presented that directly and accurately measure (i) the relative vibration between the two crystals of a double-crystal monochromator (DCM) and (ii) the absolute vibration of the second-crystal cage of a DCM. Excluding a synchrotron beam, the measurements are conducted under in situ conditions, connected to a liquid-nitrogen cryocooler. The investigated DCM utilizes a direct-drive (no gearing) goniometer for the Bragg rotation. The main causes of the DCM vibration are found to be the servoing of the direct-drive goniometer and the flexibility in the crystal cage motion stages. It is found that the investigated DCM can offer relative pitch vibration down to 48 nrad RMS (capacitive sensors, 0-5 kHz bandwidth) and absolute pitch vibration down to 82 nrad RMS (laser interferometer, 0-50 kHz bandwidth), with the Bragg axis brake engaged.
منابع مشابه
Thermal deformation of cryogenically cooled silicon crystals under intense X-ray beams: measurement and finite-element predictions of the surface shape
X-ray crystal monochromators exposed to white-beam X-rays in third-generation synchrotron light sources are subject to thermal deformations that must be minimized using an adequate cooling system. A new approach was used to measure the crystal shape profile and slope of several cryogenically cooled (liquid nitrogen) silicon monochromators as a function of beam power in situ and under heat load....
متن کاملDiamond Monochromator for High Heat Flux Synchrotron X-ray Beams
2 Single crystal silicon has been the material of choice for x-ray monochromators for the past several decades. However, the need for suitable monochromators to handle the high heat load of the next generation synchrotron x-ray beams on the one hand and the rapid and on-going advances in synthetic diamond technology on the other make a compelling case for the consideration of a diamond monochro...
متن کاملElectromagnetic Simulations for the PETRA III BPMs
1.1. PETRA III: PETRA III is a new high-brilliance synchrotron radiation source to be built at DESY, Hamburg [1]. Planned to start operation in 2009, the facility will have 14 beam lines spread along one eighth of its circumference. 40 to 960 bunches with a current of 100 mA and an emittance of 1 nm·rad will be circulated at 6 GeV. The topping up operation will ensure a stable beam. 235 beam po...
متن کاملSpherical analyzers and monochromators for resonant inelastic hard X-ray scattering: a compilation of crystals and reflections
Resonant inelastic X-ray scattering (RIXS) experiments require special sets of near-backscattering spherical diced analyzers and high-resolution monochromators for every distinct absorption-edge energy and emission line. For the purpose of aiding the design and planning of efficient RIXS experiments, comprehensive lists of suitable analyzer reflections for silicon, germanium, α-quartz, sapphire...
متن کاملA NEVI 1'AONOCHROMATOR FOR HIGH HEAT LOAD SYNCHROTRON X-RAY RADIATION* Abstract
Ali Khounsary Advanced Photon Source Argonne National Laboratory Argonne,IL60649 The high heat load associated with the powerful and concentrated x-ray beams generated by insertion devices (IDs) at a number of present and many of the future (planned or under construction) synchrotron radiation facilities poses a formidable engineering challenge for the design of monochromators and other optical...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 22 شماره
صفحات -
تاریخ انتشار 2015