Pulse Oximeter-Derived Pleth Variability Index is a Reliable Indicator of Cardiac Preload in Patients Undergoing Liver Transplantation.

نویسندگان

  • H-C Lee
  • Y-F Tsai
  • H-I Tsai
  • P C-H Chung
  • H-P Yu
  • W-C Lee
  • C-C Lin
چکیده

BACKGROUND Accurate estimation of cardiac preload during liver transplantation is essential. The right ventricular end-diastolic volume index (RVEDVI) is recognized as a good preload indicator in patients undergoing liver transplantation. Recently, dynamic variation parameters including pleth variability index (PVI) have been used as predictors of fluid responsiveness. However, the correlation between PVI and preload status has not been well studied. We evaluated the relationship between PVI and RVEDVI during liver transplantation. METHODS Eighteen patients undergoing liver transplantation were enrolled in this study. Data of hemodynamic parameters including PVI derived by Masimo Rainbow SET Pulse CO-Oximeter, central venous pressure (CVP), pulmonary arterial occlusion pressure (PAOP), and RVEDI were obtained at 10 defined time points throughout liver transplantation. The correlation between RVEDVI and CVP, PAOP, and PVI was analyzed using Spearman rank test. We also investigated the ability of PVI to accurately differentiate RVEDVI <123 or >142 mL/m(2) using receiver operating characteristic (ROC) analysis. RESULTS There was fair to good correlation between PVI and RVEDVI (correlation coefficient = -0.492, P < .001). The correlation coefficient between CVP, PAOP, and RVEDVI was 0.345 and 0.463, respectively. A 13.5% cutoff value of PVI estimated the RVEDVI <123 mL/m(2) (area under the curve [AUC] = 0.762). A 12.5% cutoff value of PVI estimated the RVEDVI >142 mL/m(2) (AUC = 0.745). CONCLUSIONS PVI presented as a reliable estimate of preload status and may be a useful predictor of fluid responsiveness in patients undergoing liver transplantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does the Pleth variability index indicate the respiratory-induced variation in the plethysmogram and arterial pressure waveforms?

BACKGROUND Respiratory variations in the pulse oximeter plethysmographic waveform amplitude (deltaPOP) are sensitive to changes in preload and can predict fluid responsiveness in mechanically ventilated patients. However, they cannot be easily calculated from a bedside monitor. Pleth variability index (PVI, Masimo Corp., Irvine, CA) is a new algorithm that automatically calculates deltaPOP. The...

متن کامل

Pleth variability index and fluid responsiveness of hemodynamically stable patients after cardiothoracic surgery.

BACKGROUND Fluid responsiveness is a measure of preload dependence and is defined as an increase in cardiac output due to volume expansion. Recent publications have suggested that variation in amplitude of the pulse oximetry waveform may be predictive of fluid responsiveness. The pleth variability index (PVI) was developed as a noninvasive bedside measurement of this variation in the pulse oxim...

متن کامل

Is the pleth variability index a surrogate for pulse pressure variation in a pediatric population undergoing spine fusion?

OBJECTIVE To compare simultaneous measurements of pulse pressure variation (PPV) and pleth variability index (PVI) in patients undergoing spinal fusion. AIMS To determine if PVI can be used as a surrogate for PPV and also the influence of the prone position on these measurements. BACKGROUND Spine fusion is an involved surgical procedure requiring attention to fluid administration. Dynamic i...

متن کامل

Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre.

BACKGROUND Respiratory variations in pulse oximetry plethysmographic waveform amplitude (DeltaPOP) can predict fluid responsiveness in mechanically ventilated patients but cannot be easily assessed at the bedside. Pleth variability index (PVI) is a new algorithm allowing for automated and continuous monitoring of DeltaPOP. We hypothesized that PVI can predict fluid responsiveness in mechanicall...

متن کامل

Pleth Variability Index predicts fluid responsiveness in critically ill patients

OBJECTIVE To investigate whether the pleth variability index, a noninvasive and continuous tool, can predict fluid responsiveness in mechanically ventilated patients with circulatory insufficiency. DESIGN Prospective study. SETTING Surgical intensive care unit of a university hospital. PATIENTS Forty mechanically ventilated patients with circulatory insufficiency in whom volume expansion ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Transplantation proceedings

دوره 48 4  شماره 

صفحات  -

تاریخ انتشار 2016