Isotropic Sub-Millimeter fMRI in Humans at 7T

نویسندگان

  • R. M. Heidemann
  • D. Ivanov
  • R. Trampel
  • J. Lepsien
  • F. Fasano
  • J. Pfeuffer
چکیده

Introduction: Ultra-high field MR scanners are used to perform brain functional MRI with a very high in-plane resolution [1,2]. Since the human cortex is convoluted in 3D, the use of isotropic voxels with high resolution is essential for fMRI to avoid partial volume effects. With higher field strength and resolution, susceptibility effects and T2* decay cause increased distortions, drop-outs and image degradation. It has been recently shown that isotropic sub-millimeter fMRI can be achieved by combining zoomed imaging (reduced FOV in PE direction) with parallel imaging [3]. In the current study we used this approach to obtain high acceleration factors of up to 5.5, which significantly improves the spatial precision of fMRI at ultra-high field strength, while avoiding the head motion artifacts of segmented acquisitions. Methods: All experiments were performed on a 7T whole-body MR scanner (MAGNETOM 7T, Siemens Healthcare Sector, Erlangen, Germany) with a 24-element phased array head coil (Nova Medical, Wilmington, MA, USA). Scans were performed on four healthy volunteers, and informed consent was obtained before each study. Since the visual stimulation set up for this coil was not yet completed, a very simple functional paradigm with blocks of 28 s stimulus-on and 28 s stimulus-off was used, with 15 epochs for a total acquisition time of 14 min. For stimulus-on a bright light was presented within the inner bore of the scanner, while for stimulus-off the light was turned off. The experiments were performed with a zoomed EPI sequence (TR = 3500 ms, TE = 27 ms, FOV = 109x156 mm, 30 slices, voxel size = 0.65x0.65x0.65 mm) with OVS using a SKEWED pulse as proposed in [1]. GRAPPA with an acceleration factor of three was used. Reconstruction was performed with a 2D convolution kernel [4] using three source points along the readout direction (RO) and two source points along phase encoding direction (PE). SPM5 was used for data analysis. Functional scans were corrected for slice timing and motion. No spatial smoothing was applied. The activation maps were corrected for multiple comparisons with a p<0.05 (FDR) and a minimum cluster size of two voxels leading to a t-score threshold of 2.8. The mean EPI image was used to coregister the activation map to the additionally acquired anatomical FLASH image. Results and Discussion: PE direction was chosen A-P to obtain less pronounced, symmetric distortions. For the head geometry of the volunteers examined in this study it would require a FOV of 200 mm to avoid aliasing in PE direction. With the zoomed approach we could use a reduced FOV of 109x156 mm, with an image matrix of 169x240. The resulting FOV in PE direction corresponds to an acceleration factor of 1.83. The combination of OVS and GRAPPA resulted in a total acceleration factor of 5.5. Figure1a shows a mean EPI image with an isotropic resolution of 0.65 mm, while Fig. 1b shows a transverse view of a coronal FLASH acquisition with 0.6 mm isotropic resolution. Obviously, there is close correspondence between the EPI images and the anatomical FLASH. The EPI image quality enables identification of very small anatomical structures, such as the stria of Gennari. In Fig. 2 the activation map is overlaid on the anatomy. The activation pattern along the calcarine sulcus is nicely presented. Conclusion: This combination of zoomed imaging with parallel imaging facilitated the very high acceleration factors required to address problems of distortion and blurring in fMRI at ultra-high field strength with high resolution. The resulting accelerated zoomed EPI images can provide fMRI data with isotropic sub-millimeter resolution. Further studies will address intra-cortical and layer-specific fMRI activations. References: [1] Pfeuffer, et al. NeuroImage 2002;17:272-86. [2] Yacoub, et al. MRM 2003;49:655-64. [3] Heidemann, et al. ISMRM 2009 #2442. [4] Griswold, 2nd Workshop on Parallel Imaging 2004; p. 16-18. Fig 1: Comparison between zoomed GRAPPA EPI with 0.65 mm isotropic resolution (a) and an anatomical FLASH image with 0.6 mm isotropic resolution (b).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Zoomed GRAPPA (ZOOPPA) for functional MRI

Introduction: High resolution EPI at high field is severely affected by T2* relaxation and susceptibility artifacts. To address both effects and to keep the echo-time (TE) short, the EPI readout duration must be reduced, which can be achieved using parallel imaging [1]. For sub-millimeter fMRI in humans large acceleration factors (AF) are essential, which are feasible at high field strength [2]...

متن کامل

Whole brain high-resolution functional imaging at ultra high magnetic fields: An application to the analysis of resting state networks

Whole-brain functional magnetic resonance imaging (fMRI) allows measuring brain dynamics at all brain regions simultaneously and is widely used in research and clinical neuroscience to observe both stimulus-related and spontaneous neural activity. Ultrahigh magnetic fields (7T and above) allow functional imaging with high contrast-to-noise ratios and improved spatial resolution and specificity ...

متن کامل

Layer specific BOLD activation in human V1 at 3 Tesla

Introduction Detection of neural responses at the laminar level in humans would significantly increase the scope and power of fMRI. To date this goal has proven elusive. In this study we demonstrate for the first time layer specific activation in humans, specifically in layer IV of V1. On the basis of this result and known blood-vessel distribution within V1 we conclude that for examinations pe...

متن کامل

A Specialized Multi-Transmit Head Coil for High Resolution fMRI of the Human Visual Cortex at 7T

PURPOSE To design, construct and validate radiofrequency (RF) transmit and receive phased array coils for high-resolution visual cortex imaging at 7 Tesla. METHODS A 4 channel transmit and 16 channel receive array was constructed on a conformal polycarbonate former. Transmit field efficiency and homogeneity were simulated and validated, along with the Specific Absorption Rate, using [Formula:...

متن کامل

Double Acquisition Background Suppressed (DABS) FAIR at 3T and 7T: advantages for simultaneous BOLD and CBF acquisition

DABS (B); 7T BOLD images using DABS at 3 mm isotropic resolution (C) and 1.5x1.5x3 mm (D). 3T perfusion weighted (PW) images at 3 mm isotropic resolution using standard FAIR (E) and with DABS (F); 7T PW images DABS 3 mm isotropic resolution (G) and 1.5x1.5x3 mm (H). All images have overlaid activated regions. Double Acquisition Background Suppressed (DABS) FAIR at 3T and 7T: advantages for simu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009