Validity of Measurement of Shear Modulus by Ultrasound Shear Wave Elastography in Human Pennate Muscle

نویسندگان

  • Naokazu Miyamoto
  • Kosuke Hirata
  • Hiroaki Kanehisa
  • Yasuhide Yoshitake
چکیده

Ultrasound shear wave elastography is becoming a valuable tool for measuring mechanical properties of individual muscles. Since ultrasound shear wave elastography measures shear modulus along the principal axis of the probe (i.e., along the transverse axis of the imaging plane), the measured shear modulus most accurately represents the mechanical property of the muscle along the fascicle direction when the probe's principal axis is parallel to the fascicle direction in the plane of the ultrasound image. However, it is unclear how the measured shear modulus is affected by the probe angle relative to the fascicle direction in the same plane. The purpose of the present study was therefore to examine whether the angle between the principal axis of the probe and the fascicle direction in the same plane affects the measured shear modulus. Shear modulus in seven specially-designed tissue-mimicking phantoms, and in eleven human in-vivo biceps brachii and medial gastrocnemius were determined by using ultrasound shear wave elastography. The probe was positioned parallel or 20° obliquely to the fascicle across the B-mode images. The reproducibility of shear modulus measurements was high for both parallel and oblique conditions. Although there was a significant effect of the probe angle relative to the fascicle on the shear modulus in human experiment, the magnitude was negligibly small. These findings indicate that the ultrasound shear wave elastography is a valid tool for evaluating the mechanical property of pennate muscles along the fascicle direction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Images in anesthesiology: shear wave elastography: novel technology for ultrasound-guided regional anesthesia.

698 September 2013 D espite the introduction of B-mode ultrasound into regional anesthesia, no evidence suggests any reduction in the incidence of unintentional intraneural injection.1 B-Mode ultrasound has several limitations: structures with similar scattering characteristics are difficult to differentiate; image quality is inconsistent among patients and deteriorates with age; and block need...

متن کامل

Quantification of dry needling and posture effects on myofascial trigger points using ultrasound shear-wave elastography.

OBJECTIVES To determine (1) whether the shear modulus in upper trapezius muscle myofascial trigger points (MTrPs) reduces acutely after dry needling (DN), and (2) whether a change in posture from sitting to prone affects the shear modulus. DESIGN Ultrasound images were acquired in B mode with a linear transducer oriented in the transverse plane, followed by performance of shear-wave elastogra...

متن کامل

Validation of shear wave elastography in skeletal muscle.

Skeletal muscle is a very dynamic tissue, thus accurate quantification of skeletal muscle stiffness throughout its functional range is crucial to improve the physical functioning and independence following pathology. Shear wave elastography (SWE) is an ultrasound-based technique that characterizes tissue mechanical properties based on the propagation of remotely induced shear waves. The objecti...

متن کامل

Non-invasive assessment of human multifidus muscle stiffness using ultrasound shear wave elastography: A feasibility study.

There is a lack of numeric data for the mechanical characterization of spine muscles, especially in vivo data. The multifidus muscle is a major muscle for the stabilization of the spine and may be involved in the pathogenesis of chronic low back pain (LBP). Supersonic shear wave elastography (SWE) has not yet been used on back muscles. The purpose of this prospective study is to assess the feas...

متن کامل

Measuring shear-wave speed with point shear-wave elastography and MR elastography: a phantom study

OBJECTIVES To compare shear-wave speed (SWS) measured by ultrasound-based point shear-wave elastography (pSWE) and MR elastography (MRE) on phantoms with a known shear modulus, and to assess method validity and variability. METHODS 5 homogeneous phantoms of different stiffnesses were made. Shear modulus was measured by a rheometer, and this value was used as the standard. 10 SWS measurements ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015