Factors to Consider When Analyzing 12 - Lead Electrocardiograms For

نویسنده

  • Nancy A. Stotts
چکیده

• Describe technical effects that can occur on ECG waveforms An important factor to consider when using findings on electrocardiograms for clinical decision making is that the waveforms are influenced by normal physiological and technical factors as well as by pathophysiological factors. Traditionally, the focus of bedside monitoring is detection of arrhythmia. However, continuous ST-segment monitoring for the detection of myocardial ischemia is now readily available. Many factors affect electrocardiographic waveforms and may interfere with diagnosis of myocardial ischemia based on electrocardiographic findings. Accordingly, a principal leadership role for clinical nurse specialists and nurse practitioners is to become knowledgeable about interpretation of 12-lead electrocardiograms and to share this knowledge with staff nurses who care for patients with acute coronary syndromes. The factors that alter electrocardiographic findings are reviewed, and the alterations that interfere with electrocardiogram-based diagnosis of myocardial ischemia are discussed. (American Journal of Critical Care. 2003;12:9-18) FACTORS TO CONSIDER WHEN ANALYZING 12-LEAD ELECTROCARDIOGRAMS FOR EVIDENCE OF ACUTE MYOCARDIAL ISCHEMIA

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Physiological Sex Age Ethnicity Height Weight Body physique Pathophysiological Arrhythmias Pacemakers Bundle

• Describe technical effects that can occur on ECG waveforms An important factor to consider when using findings on electrocardiograms for clinical decision making is that the waveforms are influenced by normal physiological and technical factors as well as by pathophysiological factors. Traditionally, the focus of bedside monitoring is detection of arrhythmia. However, continuous ST-segment mo...

متن کامل

Factors to consider when analyzing 12-lead electrocardiograms for evidence of acute myocardial ischemia.

An important factor to consider when using findings on electrocardiograms for clinical decision making is that the waveforms are influenced by normal physiological and technical factors as well as by pathophysiological factors. Traditionally, the focus of bedside monitoring is detection of arrhythmia. However, continuous ST-segment monitoring for the detection of myocardial ischemia is now read...

متن کامل

Designing a model for analyzing the development of regional universities by using Interpretative-Structural Modeling Approach

Today, causal relationships between universities and regions indicate that if there is synergy between the university system and the regional system, both sides will benefit from the value added. The purpose of this study was to present a suitable and efficient model for analyzing the development of university-region relations. In this study, mixed-exploratory research design method was used. I...

متن کامل

Accuracy of diagnosing atrial fibrillation on electrocardiogram by primary care practitioners and interpretative diagnostic software: analysis of data from screening for atrial fibrillation in the elderly (SAFE) trial.

OBJECTIVE To assess the accuracy of general practitioners, practice nurses, and interpretative software in the use of different types of electrocardiogram to diagnose atrial fibrillation. DESIGN Prospective comparison with reference standard of assessment of electrocardiograms by two independent specialists. SETTING 49 general practices in central England. PARTICIPANTS 2595 patients aged ...

متن کامل

Comparison of signal quality between EASI and Mason-Likar 12-lead electrocardiograms during physical activity.

BACKGROUND Myoelectric noise and baseline wander, artifacts that appear when patients move during electrocardiographic monitoring, can cause false alarms. This problem can be addressed by using a reduced lead set and placing electrodes on the anterior part of the torso only. The Mason-Likar modification of the standard 12-lead electrocardiogram and the EASI lead system are 2 alternative systems...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002