Inadvertent triggering of the ventilator caused by surgically placed pacer wires.
نویسندگان
چکیده
Inadvertent ventilator triggering can occur for various reasons. Leaks in the ventilator circuit, endotracheal tube leaks, tracheal cuff leaks, cardiac oscillations, water condensate causing oscillations in the circuit tubing, ventilator expiratory valve integrity, and overly sensitive triggering mechanism settings may precipitate this phenomena. We present a case of inadvertent ventilator triggering caused by electrical stimulation of the diaphragm from surgically placed pacing wires post cardiothoracic surgery. A 47-year-old woman underwent surgical placement of a left (LVAD) and right (RVAD) ventricular assist device for severe end stage cardiomyopathy, as a bridge to cardiac transplantation. The patient was observed to have inadvertent ventilator triggering while deeply sedated postoperatively. The ventilator set respiratory rate was 16 breaths/min, with patient respiratory rate of 30 breaths/min while deeply sedated. Upon assessment of ventilator waveforms and arterial blood gas revealing a profound respiratory alkalosis, the pressure/time waveform demonstrated a -2 cm H(2)O decrease in pressure prior to each cycled breath. The ventilator was subsequently changed from flow trigger sensitivity of 3 L/min to pressure trigger sensitivity of -3 cm H(2)O to eliminate the autotriggering. Later in the patient's ICU stay, inadvertent ventilator triggering was again observed. Further adjustment of the pressure trigger sensitivity to -3 cm H(2)O eliminated the autotriggering. Clinical assessment found the pacing wires were responsible for stimulating the patient's diaphragm, therefore causing airway pressure decreases and premature breath delivery. Once the electrical amplitude of the pacemaker was decreased, the inadvertent ventilator triggering resolved and normal trigger sensitivity and pH was restored.
منابع مشابه
Clinical and mechanical factors associated with the removal of temporary epicardial pacemaker wires after cardiac surgery
BACKGROUND Temporary pacemaker wires are placed in the majority of patients after cardiac surgery. There is no information on mechanical factors related to wire removal. METHODS Clinical information related to temporary wire use and removal was prospectively collected from a large cardiac surgical unit over one year. Measurements of maximal tension that nurses and doctors would apply to remov...
متن کاملRespiratory support using patient triggered ventilation in the neonatal period.
There are now a number of purpose built patient triggered ventilators for use in the newborn. These ventilators are triggered either by air flow or airway pressure changes, their triggering devices all have very high sensitivity and short systems delay. They all have the advantage that they perform well without inadvertent positive end expiratory pressure at the fast ventilator rates frequently...
متن کاملTeachers’ Limited Wait-Time Practice and Learners’ Participation opportunities in EFL Classroom Interaction
Pairing theory with methodology, this study demonstrates how EFL teachers’ limited wait-time practice structures in and affects the structuring of the unfolding classroom discourse with reference to learners’ participation opportunities. Informed by the tenets of conversation analysis, we have observed, videotaped, and transcribed line-by-line 10 EFL teachers’ naturally-occurring classroom inte...
متن کاملCoupled Thermoelasticity Impact Response Analysis of Composite Plates with SMA Wires in Thermal Environments
Impact responses of rectangular composite plates with embedded shape memory alloy (SMA) wires are investigated in the present research. The plate is assumed to be placed in a thermal environment; so that in contrast to the available researches in the field, the shape memory and ferroelasticity effects have to be considered also in addition to the superelasticity. The governing equations are der...
متن کاملDiaphragm Pacing without Tracheostomy in Congenital Central Hypoventilation Syndrome Patients.
BACKGROUND Congenital central hypoventilation syndrome (CCHS) is a rare disorder affecting central control of breathing. Thus, patients require lifelong assisted ventilation. Diaphragm pacing (DP) may permit decannulation in those who are ventilator dependent only during sleep. OBJECTIVE The purpose of this study is to determine if patients with CCHS can be successfully ventilated by DP witho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Respiratory care
دوره 57 8 شماره
صفحات -
تاریخ انتشار 2012