20-MHz ultrasound and its value in imaging of lacrimal plugs.

نویسندگان

  • Frank H W Tost
  • Jaques Darman
  • Stefan Clemens
چکیده

BACKGROUND High-frequency B scan ultrasonography is a proven method for the assessment of anterior segment diseases. Only few studies have used sonography to examine the lacrimal drainage system. We examined the proximal lacrimal drainage system by high-resolution 20-MHz ultrasound to verify the possibility to identify intracanalicular lacrimal plugs. METHODS Eight patients who had received 12 lacrimal plug implants were examined by high-resolution ultrasound. A 20-MHz sector scanner was used for detection and localization of 2 types of intracanalicular plugs (Herrick) lacrimal silicone plug, Smart trade mark acrylic polymer plug) and 1 punctum plug. Ultrasound examinations were performed 1-24 months after plug placement. Cross-sections of the lacrimal canaliculi were obtained. RESULTS The various intracanalicular implants were successfully viewed using the 20-MHz ultrasound sector scanner. Intracanalicular plugs were located at the appropriate position as intended. The silicone plugs could be seen as areas of higher reflectivity. In contrast, acrylic polymer plugs were seen as low-reflective inner structures. In a longitudinal echogram, the interface between the acrylic polymer plug and the lacrimal canaliculus produced a strong acoustic impedance. In patients with an intracanalicular acrylic polymer plug, the caliber of the plug could be ascertained and the diameter measured. CONCLUSION High-resolution ultrasound with a 20-MHz sector scanner is helpful in detecting intracanalicular plugs and is a valuable tool to assess the migration of lacrimal plugs through lacrimal canaliculi. A 20-MHz sector scanner can be used to identify and locate lacrimal plugs in the proximal drainage system even if biomicroscopic signs or clinical data are absent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of acoustic properties of silica coated gold nanoparticle as contrast agent for Ultrasonography

Interoduction: Ultrasound images have often low contrast due to small differences in acoustic impedance between different tissues. Air or gas microbubbles that surrounded by membrane are most of the contrast agents in ultrasound imaging. Problems such as instability in sound pressure and inability in penetrating from the blood vessel into body tissues limited the use of microbubbles into the in...

متن کامل

Reliability of Ultrasound Imaging of the Trunk Musculature in Athletes with and without Hamstring Injuries

Background: Trunk muscles play an important role in providing both mobility and stability during dynamic tasks in athletes.The purpose of this study was to evaluate the within-day and between-day reliability of ultrasound (US) in measuringabdominal and lumbar multifidus muscle (MF) thickness in athletes with and without hamstring strain injury (HSI).Methods: Fifteen male socce...

متن کامل

Effect of Ultrasonic Atomizer on the Yield and Yield Components of Tomato Grown in a Vertical Aeroponic Planting System

Aeroponic planting is proved to be the one of the most efficient growing environments for many vegetable crops. In this technique, plants are cultivated in absence of soil and the required nutrients are directly supplied to the roots through a fogging system. In modern sprayers, water is atomized by means of ultrasound waves. The aim of the present study was to investigate the effect of ultraso...

متن کامل

Clinical and scintigraphic comparison of silicone and polyvinylpyrrolidone coated silicone perforated plugs.

BACKGROUND/AIM Isolated stenosis of the lacrimal punctum is a frequent cause of epiphora. Treatment relies on surgical opening or dilatation with bi- or monocanalicular prosthesis. Recently, silicone perforated punctum plugs (PPP) were proposed. The drawback with these silicone PPP was that secretions accumulate in the central orifice blocking the spontaneous flow of tears. A modification of th...

متن کامل

A Comparison of Six Ultrasound Stimulation Types on Pseudomonas Aeruginosa Growth in Vitro

Background: This work evaluated the efficiency of common ultrasound stimulation (U.S.S) types on bacterial growth in vitro using clinically relevant conditions.Objective: To estimate different frequencies ultrasound bactericidal ability on bacteria in bacteria of Pseudomonas Aeruginosa. Methods: Six types of U.S.S (continuous wave, 7w/cm2, 20 KHz; continuous wave, 35w/0.8L, 40 KHz; continuous ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde

دوره 218 1  شماره 

صفحات  -

تاریخ انتشار 2004