Assessment of Corneal Biomechanical Properties and Intraocular Pressure in Myopic Spanish Healthy Population
نویسندگان
چکیده
Purpose. To examine biomechanical parameters of the cornea in myopic eyes and their relationship with the degree of myopia in a western healthy population. Methods. Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann correlated intraocular pressure (IOP), and corneal compensated IOP (IOPcc) were measured using the ocular response analyzer (ORA) in 312 eyes of 177 Spanish subjects aged between 20 and 56 years. Refraction was expressed as spherical equivalent (SE), which ranged from 0 to -16.50 diopters (D) (mean: -3.88 ± 2.90 D). Subjects were divided into four groups according to their refractive status: group 1 or control group: emmetropia (-0.50 ≤ SE < 0.50); group 2: low myopia (-0.75 ≤ SE < 3.00 D); group 3: moderate myopia (-3.00 ≤ SE ≤ -6.00 D); and group 3: high myopia (SE greater than -6.00 D). We analyzed the relationship between corneal biomechanics measured with ORA and SE. Results. CH in the emmetropia, low myopia, moderate myopia, and high myopia groups was 11.13 ± 0.98, 11.49 ± 1.25, 10.52 ± 1.54, and 10.35 ± 1.33 mmHg, respectively. CH in the highly myopic group was significantly lower than that in the emmetropic group (P = 0.07) and low myopic group (P = 0.035); however, there were no differences with the moderate myopic group (P = 0.872). There were no statistically significant differences regarding IOP among the four groups (P > 0.05); nevertheless, IOPcc was significantly higher in the moderately myopic (15.47 ± 2.47 mmHg) and highly myopic (16.14 ± 2.59 mmHg) groups than in the emmetropia (15.15 ± 2.06 mmHg) and low myopia groups (14.53 ± 2.37 mmHg). No correlation between age and the measured parameters was found. CH and IOPcc were weakly but significantly correlated with SE (r = 0.171, P = 0.002 and r = -0.131, P = 0.021, resp.). Conclusions. Present study showed only a very weak, but significant, correlation between CH and refractive error, with CH being lower in both moderately and highly myopic eyes than that in the emmetropic and low myopic eyes. These changes in biomechanical properties of the cornea may have an impact on IOP measurement, increasing the risk of glaucoma.
منابع مشابه
Corneal Biomechanics Determination in Healthy Myopic Subjects
Purpose. To determine the corneal biomechanical properties by using the Ocular Response Analyzer™ and to investigate potential factors associated with the corneal biomechanics in healthy myopic subjects. Methods. 135 eyes from 135 healthy myopic subjects were included in this cross-sectional observational study. Cornea hysteresis (CH), corneal resistance factor (CRF), cornea-compensated intraoc...
متن کاملAssessment of corneal biomechanical properties and intraocular pressure with the Ocular Response Analyzer in childhood myopia.
BACKGROUND/AIMS The authors estimated the association between corneal biomechanical properties and axial length in myopic children and verified the relationship between axial length and intraocular pressure (IOP). METHODS This cross-sectional study included 126 eyes of 63 children, aged 12.02+/-3.19 years. Corneal hysteresis (CH), corneal resistance factor (CRF), central corneal thickness (CC...
متن کاملIntraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea
Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...
متن کاملEvaluation of Corneal Deformation Analyzed with Scheimpflug Based Device in Healthy Eyes and Diseased Ones
This study was designed to evaluate the correlation between corneal biomechanical and morphological data in healthy eyes, eyes that underwent myopic photorefractive keratectomy (PRK), keratoconus affected eyes, and keratoconus affected eyes that underwent corneal collagen crosslinking (CCC). Complete clinical eye examination of all eyes was followed by tomographic (Pentacam, Oculus, Wetzlar, Ge...
متن کاملAge-related variations in corneal biomechanical properties
PURPOSE To determine age-related changes in corneal viscoelastic properties in healthy individuals. METHODS This observational cross-sectional study was performed at the Department of Ophthalmology, Imam Khomeini Hospital, Ahvaz, Iran and included 302 healthy individuals in 6 age decades (range: 10-69 years). After complete ocular examination, corneal viscoelastic properties were measured by ...