Atrioventricular conduction during long-term follow-up of patients with sick sinus syndrome.

نویسندگان

  • H R Andersen
  • J C Nielsen
  • P E Thomsen
  • L Thuesen
  • T Vesterlund
  • A K Pedersen
  • P T Mortensen
چکیده

BACKGROUND It has been claimed that patients with sick sinus syndrome have an increased risk of developing AV block, but this has never been assessed prospectively. The aim of the present study was to evaluate in a prospective trial AV conduction during the long-term follow-up of patients with sick sinus syndrome. METHODS Two hundred twenty-five consecutive patients with sick sinus syndrome and intact AV conduction were randomized to undergo single-chamber atrial pacing (110 patients) or single-chamber ventricular pacing (115 patients). Follow-up after 3 months and then yearly included measurement of the PQ interval and, in patients with atrial pacemakers, determination of the atrial stimulus-Q intervals at pacing rates of 100 and 120 bpm. The occurrence of AV block in the atrial group was recorded. During follow-up (mean, 5.5+/-2.4 years), there was no change in PQ interval in either group and no change in atrial stimulus-Q intervals or Wenckebach block point in the atrial group. Four of 110 patients in the atrial group developed grade 2 to 3 AV block that required upgrading of the pacemaker (0.6% per year). Two of these 4 patients had right bundle-branch block at pacemaker implantation. CONCLUSIONS AV conduction, estimated as PQ interval and atrial stimulus-Q interval at atrial pacing rates of 100 and 120 bpm and the Wenckebach block point, remains stable during long-term follow-up. Thus, treatment with single-chamber atrial pacing is safe and can be recommended to patients with sick sinus syndrome without bundle-branch block.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heart failure and echocardiographic changes during long-term follow-up of patients with sick sinus syndrome randomized to single-chamber atrial or ventricular pacing.

BACKGROUND In patients with sick sinus syndrome, choice of pacing mode has been implicated in the development of congestive heart failure. METHODS AND RESULTS A total of 225 consecutive patients with sick sinus syndrome and intact atrioventricular conduction were randomized to either single-chamber atrial pacing (n = 110) or single-chamber ventricular pacing (n = 115). Clinical assessment inc...

متن کامل

[Clinical safety and efficacy of single-chamber atrial pacing in sick sinus syndrome: long-term follow-up].

INTRODUCTION AND OBJECTIVES Although atrial pacing is a more physiological mode of stimulation in sinus node dysfunction, the pacing modes most often are used DDD and VVI. The aim of our study was to demonstrate that AAI/AAIR pacing is effective and safe by analyzing the complications and mortality of this pacing mode in a long-term follow-up study. PATIENTS AND METHOD Between 1982 and 2000 d...

متن کامل

Benefits of dual chamber pacing in sick sinus syndrome.

The effects of DDD (fully automatic) and VVI (ventricular demand) pacing modes on exercise tolerance, symptom diary cards, and Holter monitoring were investigated in a randomised double blind crossover study of 16 patients who had had DDD pacemakers implanted because of frequent syncope. Eight patients presented with sick sinus syndrome and, with one exception, retrograde atrioventricular condu...

متن کامل

A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome: echocardiographic and clinical outcome.

OBJECTIVES A randomized trial was done to compare single-chamber atrial (AAI) and dual-chamber (DDD) pacing in patients with sick sinus syndrome (SSS). Primary end points were changes in left atrial (LA) size and left ventricular (LV) size and function as measured by M-mode echocardiography. BACKGROUND In patients with SSS and normal atrioventricular conduction, it is still not clear whether ...

متن کامل

The relationship between sinoatrial conduction time and sinus cycle length during spontaneous sinus arrhythmia in adults.

It is well known that atrioventricular conduction varies as a function of atrial rate. However, rate related changes in sinoatrial conduction time (SACT) have not been examined. To determine the relationship between SACT and sinoatrial cycle length (SCL) in man, atrial and His bundle electrograms were recorded during atrial premature stimulation in each of nineteen patients with sinus arrhythmi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 98 13  شماره 

صفحات  -

تاریخ انتشار 1998