Magnetic resonance imaging in epilepsy with a fast FLAIR sequence.

نویسندگان

  • U C Wieshmann
  • S L Free
  • A D Everitt
  • P A Bartlett
  • G J Barker
  • P S Tofts
  • J S Duncan
  • S D Shorvon
  • J M Stevens
چکیده

OBJECTIVE To assess the diagnostic value of the fast FLAIR sequence in patients with epilepsy. METHODS One hundred and twenty eight patients with epilepsy and 10 control subjects were scanned with the fast FLAIR sequence with 5 mm slices, a coronal gradient echo (GRE) T1 weighted sequence with 1.5 mm slices and spin echo (SE) or fast spin echo (FSE) proton density and T2 weighted sequences with 5 mm slices. All images were compared by an unblinded neuroradiologist and neurologist. Fast FLAIR images of patients with hippocampal sclerosis (HS) and normal control subjects were also evaluated by two blinded independent raters. RESULTS Fast FLAIR provided a high conspicuity of neocortical damage, hamartomas, dysembryoplastic neuroepithelial tumours, and clear cut hippocampal sclerosis. However, the same information could be obtained from the coronal T1 and T2 weighted images. In three patients fast FLAIR showed a clearly abnormal signal when SE T2 weighted images had not been definitely abnormal. Heterotopia was less conspicuous on fast FLAIR than GRE T1 weighted images. The two blinded raters detected all but one of the patients with clear cut hippocampal sclerosis on fast FLAIR images but missed all borderline cases of hippocampal atrophy and there were two false positives. Clear cut hippocampal sclerosis was more conspicuous on fast FLAIR images than on SE T2 weighted images in most patients, but additional patients were not identified. CONCLUSION Fast FLAIR has the advantage of identifying neocortical lesions and definite hippocampal sclerosis with a short scanning time and may also demonstrate lesions when other sequences are normal in a limited number of cases. The technique was not useful, however, for identifying mild hippocampal sclerosis or heterotopia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques

Background and objective: Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don’t have MS plaques or MRI images are not enough optimized enough in order to show MS plaques? The aim of the current study is ...

متن کامل

Diagnosis of Meningitis Caused by Pathogenic Microorganisms Using Magnetic Resonance Imaging: A Systematic Review

Introduction: Bacterial meningitis is an acute infectious inflammation of the protective membranes covering the brain. Its early diagnosis is vital because of its high morbidity and mortality. It is mostly diagnosed by a gold standard diagnostic tool i.e. Cerebrospinal Fluid (CSF) analysis. However, it is sometimes difficult and or impossible to do this procedure and an alternative diagnostic t...

متن کامل

Magnetic resonance imaging in partial epilepsy: additional abnormalities shown with the fluid attenuated inversion recovery (FLAIR) pulse sequence.

Thirty six patients with a history of partial epilepsy had MRI of the brain performed with conventional T1 and T2 weighted pulse sequences as well as the fluid attenuated inversion recovery (FLAIR) sequence. Abnormalities were found in 20 cases (56%), in whom there were 25 lesions or groups of lesions. Twenty four of these lesions were more conspicuous with the FLAIR sequence than with any of t...

متن کامل

Use of Magnetic Resonance Imaging in Food Quality Control: A Review

Modern challenges of food science require a new understanding of the determinants of food quality and safety. Application of advanced imaging modalities such as magnetic resonance imaging (MRI) has seen impressive successes and fast growth over the past decade. Since MRI does not have any harmful ionizing radiation, it can be considered as a magnificent tool for the quality control of food prod...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurology, neurosurgery, and psychiatry

دوره 61 4  شماره 

صفحات  -

تاریخ انتشار 1996