Assessment of the time constant of relaxation: insights from simulations and hemodynamic measurements.

نویسندگان

  • S De Mey
  • J D Thomas
  • N L Greenberg
  • P M Vandervoort
  • P R Verdonck
چکیده

The objective of this study was to use high-fidelity animal data and numerical simulations to gain more insight into the reliability of the estimated relaxation constant derived from left ventricular pressure decays, assuming a monoexponential model with either a fixed zero or free moving pressure asymptote. Comparison of the experimental data with the results of the simulations demonstrated a trade off between the fixed zero and the free moving asymptote approach. The latter method more closely fits the pressure curves and has the advantage of producing an extra coefficient with potential diagnostic information. On the other hand, this method suffers from larger standard errors on the estimated coefficients. The method with fixed zero asymptote produces values of the time constant of isovolumetric relaxation (tau) within a narrow confidence interval. However, if the pressure curve is actually decaying to a nonzero pressure asymptote, this method results in an inferior fit of the pressure curve and a biased estimation of tau.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of Lid Driven Cavity Flow at Different Aspect Ratios Using Single Relaxation Time Lattice Boltzmann Method

Abstract   Due to restrictions on the choice of relaxation time in single relaxation time (SRT) models, simulation of flows is generally limited base on this method. In this paper, the SRT lattice Boltzmann equation was used to simulate lid driven cavity flow at different Reynolds numbers (100-5000) and three aspect ratios, K=1, 1.5 and 4. The point which is vital in convergence of this scheme ...

متن کامل

Investigating Impacts of Sustainable Repair Time and Circuit Breaker Model on Meshed Distribution Networks Reliability Assessment

Generally, the failure rate and the repair time of system components are constant parameters in reliability assessment of electric distribution systems. A failure of component is resulted from failing in the operation or overloading. In addition, there exist cases where, the repair times of components are small and tolerable from customer point of view. Thus, tolerable repair times may be overl...

متن کامل

Doppler-Derived Myocardial Performance Index in Healthy Children in Shiraz

Background: Assessment of myocardial function is essential in heart disease, but in regard to systolic and diastolic functions such evaluation has limitation. Ejection fraction is difficult to assess in abnormally-shaped ventricles, and diastolic inflow velocity pattern may be fused because of tachycardia. Objective: A myocardial performance index (MPI) or Tei index has been developed for adult...

متن کامل

محاسبه کوانتمی خواص ساختاری، الکترونی و ترموالکتریکی بلور AgSbSe2

In this work, density functional calculations and Boltzmann semiclassical theory of transport are used to investigate structural, electronic, and thermoelectric properties of AgSbSe2 crystal. According to the published experimental measurements, five more likely structures of this compound are considered and their structural and electronic properties are calculated and compared together. Then, ...

متن کامل

توانایی اکوکاردیوگرافی داپلر در تخمین فشار پرشدگی بطن چپ در تنگی دریچه میترال

Background: Estimation of Left Ventricular End Diastolic Pressure (LVEDP) among patients with Mitral Stenosis (MS) helps to diagnose diastolic dysfunction and to explain their symptoms. However, Conventional Doppler measurements have limitation in predicting of LVEDP. This study sought to establish whether the correlation between measurements derived from Tissue Doppler echocardiography and LVE...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 280 6  شماره 

صفحات  -

تاریخ انتشار 2001