Comparison of ultrasound quality assurance phantom measurements from matched and mixed scanner‐transducer combinations

نویسندگان

  • D. J. Tradup
  • N. J. Hangiandreou
  • J. P. Taubel
چکیده

Our goal in this work was to compare the results of common phantom tests made using matched and mixed ultrasound (US) scanner-transducer combinations. Sets of common US quality assurance (QA) measurements were made using matched US scanner-transducer combinations (i.e., transducers purchased for use with a particular scanner), as well as unmatched (mixed) combinations. Measurements of vertical and horizontal distance accuracy, and depth of penetration were performed using three common transducer types. Means, standard deviations, and differences between the mean mix and match measurements divided by the standard deviation (match-mix difference, or MMD), and two-sided, paired t-tests were computed for the groups of mixed and matched measurements. MMDs for vertical and horizontal distance accuracy test results were less than 0.87 in all cases, well below our threshold value of 2.0, which indicates that a significant difference exists. MMDs for the depth of penetration measurements were less than 1.50, again below the threshold value. These results suggest that all of the mixed and matched data sets were very similar. The more sensitive t-tests indicate statistically significant differences in only 2 of the 18 pairs of data sets. In conclusion, this study suggests that QA measurements generated by mixed or matched scanner-transducer combinations are very comparable. The ability to obtain QA phantom test data from mixed scanner-transducer combinations reduces the time required for US QA testing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phantom-based quality assurance measurements in B-mode ultrasound

BACKGROUND Recommended phantom-based quality assurance measurements in B-mode ultrasound (US) may be tedious. For the purpose of cost-effective US quality assurance it is important to evaluate measurements that effectively reflect the quality of US scanner. PURPOSE To find out which recommended phantom-based quality assurance measurements are effective in detecting dead or weak transducer ele...

متن کامل

A Comparative Study on the Influence of Probe Placement on Quality Assurance Measurements in B-mode Ultrasound by Means of Ultrasound Phantoms

To check or to prevent failures in ultrasound medical systems, some tests should be scheduled for both clinical suitability and technical functionality evaluation: among them, image quality assurance tests performed by technicians through ultrasound phantoms are widespread today and their results depend on issues related to scanner settings as well as phantom features and operator experience. I...

متن کامل

Ultrasound Equipment Quality Assurance

Components of an Ultrasound Quality Assurance Program 257 Quality Assurance and Preventive Maintenance 257 Tissue-Mimicking Phantoms 257 Tissue Properties Represented in Phantoms 257 Typical Quality Assurance Phantom Design 257 Cautions About Phantom Desiccation 258 Basic Quality Control Tests 259 Visual Inspection 259 Transducer Choice 259 System Sensitivity 260 Photography and Gray-Scale Hard...

متن کامل

Diagnostic Ultrasound Scanner Quality Assurance

Medical Physics at CancerCare Manitoba has developed its own ultrasound phantom. The following table is intended as a quick reference guide when performing the quality assurance measurements. Instructions Limits Record Items Required ultrasound contrast-detail phantom degassed water or coupling gel paper towels for clean up (optional) lab stand and clamp to hold probe Physical check: 1. probe s...

متن کامل

Thermochromic phantom for therapeutic ultrasound daily quality assurance

Background/introduction Errors in power output ranging from −100% to +210% have been reported in a multitude of physiotherapy transducers.[1] Differences in power output can arise even after careful calibration on an annual or bi-annual schedule, which can either result in harm to the patient or non-effective treatment. Therefore, easy implementation of daily quality assurance is of great impor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2003