چکیده

BACKGROUND Although the World Society for Abdominal Compartment Syndrome in its guidelines recommends midaxillary line (MAL) as zero reference level in intra-abdominal pressure (IAP) measurements in aiming at standardizing the technique, evidence supporting this suggestion is scarce. The aim of this study is to study if the zero reference position influences bladder pressure measurements as estimate for IAP. METHODS The IAP of 100 surgical patients was measured during the first 24 h of admission to the surgical intensive care unit of General Calixto Garcia Hospital in Havana (Cuba) following laparotomy. The period was January 2009 to January 2010. The IAP was measured twice with a six-hour interval using the transurethral technique with a priming volume of 25 ml. IAP was first measured with the zero reference level placed at MAL (IAPMAL), followed by a second measurement at the level of the symphysis pubis (SP) after 3 minutes (IAPSP). Correlations were made between IAP and body mass index (BMI), type of surgery, gender, and age. RESULTS Mean IAPMAL was 8.5 ± 2.8 mmHg vs. IAPSP 6.5 ± 2.8 mmHg (p < 0.0001). The bias between measurements was 2.0 ± 1.5, 95% confidence interval of 1.4 to 3.0, upper limit of 4.9, lower limit of -0.9, and a percentage error of 35.1%. IAPMAL was consistently higher than IAPSP regardless of the type of surgery. The BMI correlated with IAP values regardless of the zero reference level (R2 = 0.4 and 0.3 with IAPMAL and IAPSP respectively, p < 0.0001). CONCLUSIONS The zero reference level has an important impact on IAP measurement in surgical patients after laparotomy and can potentially lead to over or underestimation. Further anthropometric studies are needed with regard to the relative MAL and SP zero reference position in relation to the theoretical ideal reference level at midpoint of the abdomen. Until better evidence is available, MAL remains the recommended zero reference position due to its best anatomical localization at iliac crest.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

Effect of Islamic fasting on mean arterial pressure

Introduction: World Health Organization (WHO) introduced hypertension as an epidemic in developing countries. However, hypertension is adequately controlled in only 12.5% of patients.  The aim of this study was to evaluate the relationship between Ramadan fasting and mean arterial pressure (MAP). Methods: This clinical, observational study was carried out at Medical O.P.D of Jinnah Medical Coll...

متن کامل

Comparing intra-abdominal pressures in different body positions via a urinary catheter and nasogastric tube: a pilot study

OBJECTIVES Intra-abdominal pressure (IAP) is most commonly measured via the bladder with the patient in the supine position. In the ICU, patients are nursed with the head of the bed elevated at 30° (HOB30) to reduce the risk of ventilator-associated pneumonia. This study investigated whether gastric pressure at HOB30 can be used as a surrogate measure of IAP via the bladder in the supine positi...

متن کامل

Comparison of pressures measured from the proximal external jugular vein and from a central vein.

Sir,—The study by Shah, Swai and Latto (1986) comparing the venous pressures measured from the proximal external jugular vein and from a central vein was interesting. The authors found a mean difference in pressure of 3 mm Hg from the two sites which was not influenced by alterations in the head position or the side of jugular venous catheterization. Whether the reference zero is the right atri...

متن کامل

بررسی تاثیر تغییر وضعیت بدن بر فشار کاف لوله تراشه در بیماران تحت تهویه مکانیکی

Background: Endotracheal tube cuff pressure must be maintained in safe range. Many factors could be affecting on endotracheal tube cuff pressure in patients on mechanical ventilation. Patients undergoing mechanical ventilation (MV) in critical care settings require changing position for different reasons. The aim of this study was to determine the effect of changes in body position and head of ...