High-resolution diffusion-weighted imaging of neck lymph nodes using 2D-single-shot interleaved multiple inner volume imaging diffusion-weighted echo-planar imaging at 3T.
نویسندگان
چکیده
BACKGROUND AND PURPOSE 2D-ss-IMIV-DWEPI is an ss-DWEPI with greatly reduced geometric distortion. The purposes of this paper are to 1) evaluate of the utility of 2D-ss-IMIV-DWEPI for high-resolution neck LN imaging; 2) determine whether 2D-ss-IMIV-DWEPI can depict normal LN hilum; and 3) evaluate whether the inclusion of LN hilum within ROIs affects the measured LN ADC. MATERIALS AND METHODS HR-DWI was acquired with 1-mm² in-plane resolution and 2-mm section thickness by using 2D-ss-IMIV-DWEPI. In total, 58 LNs from 18 subjects were evaluated. The ADC map was calculated by using DWI with b = 10 and 300 s/mm². In those LNs where the LN hilum could be recognized, the LN ADC was measured with and without inclusion of the hilum, and the mean difference of the resulting ADC values was determined. RESULTS The hilar structure was identified by DWI in 15 LNs. The ADC of the hilum was 1.981 ± 0.331 × 10⁻³ mm²/s. In these 15 LNs, the ADC value excluding hilar structure was significantly lower than the ADC value including hilar structure (0.983 ± 0.169 versus 1.206 ± 0.244 × 10⁻³ mm²/s; P < .0001). The mean ADC in a total of 58 LNs excluding the hilar structure was significantly lower than the value obtained including the hilar structure (1.034 ± 0.183 versus 1.095 ± 0.213 × 10⁻³ mm²/s; P = .0002). CONCLUSIONS HR-DWI of neck LNs obtained by using 2D-ss-IMIV-DWEPI could identify the hilar structure. The ADC of normal neck LNs seemed significantly different when the hilum was included. The results suggest that HR-DWI may be helpful to aid selection of proper ROIs within LNs for accurate and reliable ADC measurements.
منابع مشابه
Joint correction of Nyquist artifact and minuscule motion-induced aliasing artifact in interleaved diffusion weighted EPI data using a composite two-dimensional phase correction procedure.
Diffusion-weighted imaging (DWI) obtained with interleaved echo-planar imaging (EPI) pulse sequence has great potential of characterizing brain tissue properties at high spatial-resolution. However, interleaved EPI based DWI data may be corrupted by various types of aliasing artifacts. First, inconsistencies in k-space data obtained with opposite readout gradient polarities result in Nyquist ar...
متن کاملHigh-resolution, Anatomically-accurate Diffusion-weighted Imaging of Orbital and Sinonasal Lesions with RESOLVE
Diffusion-weighted imaging is a core sequence in clinical routine imaging for many anatomical regions including the brain, abdomen, breasts, and pelvis [1, 2]. Conventionally, diffusion-weighted imaging is acquired using a single-shot diffusion-weighted echo planar imaging (EPI) sequence with the primary advantages of insensitivity to motion-induced phase errors and relatively short acquisition...
متن کاملHigh resolution diffusion-weighted imaging using readout-segmented echo-planar imaging, parallel imaging and a two-dimensional navigator-based reacquisition.
Single-shot echo-planar imaging (EPI) is well established as the method of choice for clinical, diffusion-weighted imaging with MRI because of its low sensitivity to the motion-induced phase errors that occur during diffusion sensitization of the MR signal. However, the method is prone to artifacts due to susceptibility changes at tissue interfaces and has a limited spatial resolution. The intr...
متن کاملRobust fat suppression at 3T in high-resolution diffusion-weighted single-shot echo-planar imaging of human brain.
Single-shot echo-planar imaging is the most common acquisition technique for whole-brain diffusion tensor imaging (DTI) studies in vivo. Higher field MRI systems are readily available and advantageous for acquiring DTI due to increased signal. One of the practical issues for DTI with single-shot echo-planar imaging at high-field is incomplete fat suppression resulting in a chemically shifted fa...
متن کاملIsotropic resolution in Diffusion Weighted Imaging using 3D multi-slab, multi-echo Echo Planar Imaging
INTRODUCTION Diffusion weighted Magnetic Resonance Imaging (DWI) is usually performed using a 2D single shot echo planar imaging technique, because it generates good SNR, short scan times and is immune to phase differences between diffusion-encoded excitations. 2D DWEPI can be acquired with a reasonably high in-plane resolution, especially if parallel imaging is used to reduce the geometric dis...