Two-Year Clinical Follow-Up After Sirolimus-Eluting Versus Bare-Metal Stent Implantation Assisted by Systematic Glycoprotein IIb/IIIa Inhibitor Infusion in Patients With Myocardial Infarction
نویسنده
چکیده
Results The cumulative incidence of death, myocardial infarction (MI), or target vessel revascularization (TVR) remained lower in the tirofiban-SES compared with the abciximab-BMS group at 2 years (24.2% vs. 38.6%, respectively; hazard ratio [HR] 0.56 [95% confidence interval (CI) 0.33 to 0.98]; p 0.038). The composite of death/MI was similar in the tirofiban-SES (16.1%) and the abciximab-BMS groups (20.5%, HR 0.77 [95% CI 0.38 to 1.55]; p 0.43) while the need for TVR was markedly reduced (9.8% vs. 25.5%, respectively; HR 0.34 [95% CI 0.16 to 0.77]; p 0.01) in the tirofiban-SES arm. The rate of confirmed, probable, or possible stent thrombosis did not differ in the 2 groups, nor the incidence of death/MI after thienopyridine discontinuation.
منابع مشابه
Two-year clinical follow-up after sirolimus-eluting versus bare-metal stent implantation assisted by systematic glycoprotein IIb/IIIa Inhibitor Infusion in patients with myocardial infarction: results from the STRATEGY study.
OBJECTIVES We sought to investigate whether the previously reported midterm clinical benefit of planned sirolimus-eluting stent (SES) implantation in patients with ST-segment elevation myocardial infarction (STEMI) was maintained over a 24-month time period. Moreover, the distribution of clinical events in relation to thienopyridine discontinuation was thoroughly investigated. BACKGROUND No r...
متن کاملDrug-Eluting Stents
c s c u r r d t m t p s p a t l t a B b w d a t a 0 d S o s rug-eluting stents have been the most successful strategy or the prevention of restenosis after percutaneous coronary nterventions (1). In line with this, the STRATEGY Single High-Dose Bolus Tirofiban and Sirolimus Eluting tent versus Abciximab and Bare Metal Stent in Acute yocardial Infarction) study showed a marked decrease in he nee...
متن کاملIntraprocedural stent thrombosis during implantation of sirolimus-eluting stents.
BACKGROUND Intraprocedural stent thrombosis (IPST) is a rare event (<0.01% in our experience with bare metal stents), with the exception of specific settings such as acute myocardial infarction, thrombus-containing lesions, and dissections. We report the occurrence of this event during elective implantation of sirolimus-eluting stents. METHODS AND RESULTS Between April 2002 and August 2003, 6...
متن کاملSafety and efficacy of sirolimus- and paclitaxel-eluting coronary stents.
BACKGROUND The safety of drug-eluting stents has been called into question by recent reports of increased stent thrombosis, myocardial infarction, and death. Such studies have been inconclusive because of their insufficient size, the use of historical controls, a limited duration of follow-up, and a lack of access to original source data. METHODS We performed a pooled analysis of data from fo...
متن کاملSeven-Year Clinical Outcomes of Sirolimus-Eluting Stent Versus Bare-Metal Stent: A Matched Analysis From A Real World, Single Center Registry
The aim of this study is to compare clinical outcomes for seven years, between sirolimus-eluting stent (SES) and bare metal stent (BMS). During the BMS and drug-eluting stent (DES) transition period (from April 2002 to April 2004), 434 consecutive patients with 482 lesions underwent percutaneous coronary intervention, using BMS or SES. Using propensity score matching, 186 patients with BMS and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2007