How many diffusion gradient directions are required for HARDI?
نویسندگان
چکیده
Introduction: While the minimum number of directions required for robust diffusion tensor imaging (DTI) has been extensively studied [1-4], the equivalent studies have not been performed for high angular resolution diffusion-weighted imaging (HARDI) methods. This is due in part to the fact that many HARDI methods are available, each with their own requirements and parameters, making it difficult to select an appropriate outcome measure. It is also difficult to replicate the data acquisition strategies that have been employed in the original DTI studies, which consisted of acquiring a number of schemes with different numbers of directions and repeats, while keeping the total number of images constant (e.g. 10×6, 5×12, 3×20, 2×30, 1×60). This strategy was possible with DTI due to the known theoretical minimum number required (i.e. 6), and the fact that this number was sufficiently low to keep the total scan time feasible. In this study, we use an approach based on sampling theory to determine the minimum number of DW directions required for HARDI experiments, independent of the particular algorithm used. Theory: The diffusion-weighted (DW) signal measured as a function of orientation (referred to here as the signal profile) can be viewed as a 2D waveform defined over the sphere. The number of unique sampling directions needs to be sufficiently large to provide a proper characterisation of all the features of the signal profile. This can be appreciated using a Cartesian Fourier analogy: the Nyquist criterion states that the minimum sampling frequency required to fully characterise a waveform is twice the maximum frequency component contained in that waveform. Similarly, the minimum sampling frequency in the angular domain required to fully characterise a waveform over the sphere is determined by its maximum angular frequency content. The spherical harmonic (SH) series provides a rigorous framework to characterise these angular frequencies. If the signal profile can be shown to contain no significant SH terms beyond a given harmonic order lmax, then the minimum number N of unique directions required to fully characterise it is given simply by the number of SH coefficients contained in the SH series up to lmax, N = 1⁄2(lmax+1)(lmax+2). Note that only even harmonic orders are needed due to the symmetry of the diffusion process. The signal profile will be sharpest, and hence contain the highest angular frequency content, in regions containing a single coherently oriented fibre population. This can be more readily appreciated by considering the problem within the spherical deconvolution framework [5]: the signal profile within a crossing fibre region is given by the spherical convolution of the fibre orientation distribution (FOD) with the signal profile for a single fibre orientation. According to the convolution theorem, convolution over one domain (the sphere) is equivalent to multiplication in the other domain (angular frequency). Hence, the signal profile measured in a crossing fibre region cannot contain higher angular frequencies than were already present in the single-fibre signal profile. In addition, the signal profile in single-fibre regions can be assumed to be axially symmetric. This is a substantial advantage, since in this case only one free parameter (the m=0 coefficient) needs to be estimated per harmonic order l instead of 2l+1 for the non-axially symmetric case. Methods: The frequency content of the signal profile was estimated in two ways. First, the noiseless signal profile was simulated for a single fibre population using the diffusion tensor model, assuming a b-value of 3000 s/mm and literature values for the mean ADC and FA of 500 × 10 mm/s and 0.7 respectively [6]. The m=0 (axially symmetric) SH coefficients of the simulated DW signal were then estimated using a least-squares fit. Second, the signal profile was measured directly from a high-quality in-vivo data set, acquired from a healthy volunteer using a 3T Siemens Trio MRI system. Acquisition parameters were: b = 3000 s/mm, TE = 110 ms, 3 mm isotropic voxels, 30 contiguous slices, 500 uniformly distributed DW gradient directions, 25 b=0 images, scan time: ~36 minutes. The analysis was restricted to the set of voxels with FA greater than 0.6, since these were assumed to contain a single fibre population. Within each voxel, the m=0 (axially symmetric) SH coefficients of the signal profile were estimated using a maximum likelihood estimation procedure. The likelihood of the data within each single-fibre voxel, given the set of m=0 SH coefficients {sl} and the noise σ is given by:
منابع مشابه
How Many Gradients are Sufficient in High-Angular Resolution Diffusion Imaging (HARDI)?
Introduction: High-angular resolution diffusion imaging (HARDI) is a powerful extension of MRI that maps the directional diffusion of water in the brain, based on applying diffusion-sensitized gradients in 30-100 or more different directions. In the Diffusion Tensor (DT) model, a tensor is fitted to the set of diffusion images, and maps of fiber integrity such as fractional or relative anisotro...
متن کاملAnalysis of Fiber Reconstruction Accuracy in High Angular Resolution Diffusion Images (HARDI)
Introduction: High angular resolution diffusion imaging (HARDI) is a powerful extension of MRI that maps the directional diffusion of water in the brain. With more diffusion gradients and directions, fiber directions may be tracked with greater angular precision, fiber crossings can be resolved, and anisotropy measures can be derived from the full fiber orientation density function. To better r...
متن کاملDetermination of Fiber Direction in High Angular Resolution Diffusion Images using Spherical Harmonics Functions and Wiener Filter
Diffusion tensor imaging (DTI) MRI is a noninvasive imaging method of the cerebral tissues whose fibers directions are not evaluated correctly in the regions of the crossing fibers. For the same reason the high angular resolution diffusion images (HARDI) are used for estimation of the fiber direction in each voxel. One of the main methods to specify the direction of fibers is usage of the spher...
متن کاملA Study of Information Gain in High Angular Resolution Diffusion Imaging (HARDI)
Diffusion weighted magnetic resonance (MR) imaging is a powerful tool to investigate white matter microstructure, by mapping local 3D displacement profiles of water molecules in brain tissue. Highangular resolution diffusion imaging (HARDI) schemes have been employed to resolve fiber crossing and more complex diffusion geometries. Most recently, the tensor distribution function (TDF) has been p...
متن کاملDiffusion Simulation Tractography for High Angular Resolution Diffusion Imaging
Introduction While the standard diffusion tensor imaging (DTI) approach has proven to be a valuable tool in detecting local tissue structure and reconstructing neural fiber networks in brain, it cannot accurately reveal the white matter structure in the presence of multiple fiber orientations within a single voxel. In particular, for crossed fibers, the second-order diffusion tensor model fails...
متن کاملBuilding an Average Population HARDI Atlas
We present a framework to build a High Angular Resolution Diffusion Image (HARDI) Atlas based on a population of HARDIs from different subjects. The method relies on a non-linear group-wise registration algorithm as well as a set of tools to re-orient the gradient directions of individual subjects and re-interpolate their diffusion weighted signal in a canonical gradient direction set in atlas ...