Under-sampling in PET scanners as a source of image blurring

نویسندگان

  • James
  • N. Tomic
چکیده

The spatial resolution of PET scanners is degraded by a number of causes, both fundamental to the nature of positron decay, and to detectors. The crystal dimensions, their placement in the block and readout all contribute to the loss of resolution. We investigated the relative effects of sampling of the image space by the detectors, and the use of block detectors in a whole body PET scanner on resolution degradation. Three sources were mounted on a linear translation stage which moved them trans-axially through the central field of a Siemens CTI HR+ PET scanner. A 140 frame study was acquired as the sources moved horizontally 0.5mm between frames. The vertical projection from each frame was summed over all slices. The FWHM of each source’s representation was estimated in each frame in the summed projections. The response functions were much sharper from crystals at the edge of the detector blocks, than from those from the central crystals. They were consistent with the effects of source size, non-collinearity, and crystal dimensions. The response from the central crystals were degraded by an additional term of 1.2mm added in quadrature to the other blurring effects. The intensity of the image of a small source depended on the source location, as did the FWHM of the response of the central crystals in the block detectors. The response functions of edge crystals were found to be sharper than those of the central crystals in the block detectors. However, a more interesting finding is that when very small sources are imaged in PET scanners their apparent intensity and their associated response functions depend on their location along any projection. This under-sampling results in resolution loss equivalent to about 1 2 of the crystal width. r 2005 Elsevier B.V. All rights reserved. PACS: 87.59.V; 87.59; 87.62

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE

  Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...

متن کامل

Single scan parameterization of space-variant point spread functions in image space via a printed array: the impact for two PET/CT scanners.

Incorporation of a resolution model during statistical image reconstruction often produces images of improved resolution and signal-to-noise ratio. A novel and practical methodology to rapidly and accurately determine the overall emission and detection blurring component of the system matrix using a printed point source array within a custom-made Perspex phantom is presented. The array was scan...

متن کامل

Design and performance evaluation of spheroid geometry for brain PET scanner using Monte Carlo modeling

Introduction: There has been a curiosity about the spheroid geometry for PET scanners developments since several years ago, therefore in this study, we are aiming to evaluate the performance of this geometry and compare its performance with cylindrical geometry using Monte Carlo simulation. Methods: We simulated a spheroid geometry with a radius of 199 mm...

متن کامل

Pragmatic fully 3D image reconstruction for the MiCES mouse imaging PET scanner.

We present a pragmatic approach to image reconstruction for data from the micro crystal elements system (MiCES) fully 3D mouse imaging positron emission tomography (PET) scanner under construction at the University of Washington. Our approach is modelled on fully 3D image reconstruction used in clinical PET scanners, which is based on Fourier rebinning (FORE) followed by 2D iterative image reco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005