Preliminary assessment of turbo spectroscopic imaging for targeting in brain biopsy.

نویسندگان

  • A J Martin
  • H Liu
  • W A Hall
  • C L Truwit
چکیده

BACKGROUND AND PURPOSE Brain biopsy remains an integral and necessary component in the diagnosis of brain lesions. We assessed the ability of turbo spectroscopic imaging (TSI) to provide a physiologically based target for tissue sampling. METHODS TSI was performed in 26 anesthetized patients immediately before MR-guided brain biopsy. In 10 patients, single-voxel spectroscopy was performed on the TSI-indicated target and correlated with the TSI findings. Biopsy samples were taken from the imaging and spectroscopically defined target(s) under MR guidance, and pathologic findings were compared with preoperative spectra. RESULTS TSI alone provided a definitive target based on a region of elevated choline in 17 of 21 patients in whom a neoplasm was confirmed. The remaining four neoplasms exhibited relatively low metabolic levels and were difficult to distinguish from the five cases of radiation necrosis seen in this study. TSI findings were in qualitative agreement with those obtained at single-voxel spectroscopy, although TSI spectra exhibited more contamination. Quantitative spectral analysis of TSI data is limited by low spectral resolution. CONCLUSION TSI is helpful for determining an appropriate biopsy target in heterogeneous lesions. Coupling TSI targeting with conventional imaging and intraoperative confirmation of needle positioning resulted in a 100% diagnostic success rate and increased the clinician's confidence in the histologic findings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

18F-FDG PET/CT usefulness vs Tc99m-Tetrofosmin in the assessment of malignant brain gliomas: Report of two cases

Gliomas account for almost 80% of primary malignant brain tumors in adults. Magnetic Resonance imaging (MRI) is still the gold standard for diagnosis of brain tumors and brain 99mTc-tetrofosmin Single Photon Emission Computed Tomography (99mTc-tetrofosmin-SPECT) has been established as a useful tool for their evaluation. Fluorine-18–2-fluoro-2-deoxy-d-glucose positron emi...

متن کامل

Preparation and preliminary studies of [64Cu]-antiMUC-1 for breast cancer targeting

PR81 is a monoclonal antibody that binds with high affinity to MUC1 that over expressed on breast tumors. PR81 is considered a suitable targeting molecule that was radiolabeled using Cu-64 for positron imaging studies. The monoclonal antibody was conjugated with DOTA moiety and after purification was evaluated for radiochemical purity, immunoreactivity, cell toxicity and structure integrity as ...

متن کامل

Turbo STIR magnetic resonance imaging as a whole-body screening tool for metastases in patients with breast carcinoma: preliminary clinical experience.

This study was undertaken to assess the utility of whole-body turbo short tau inversion recovery (STIR) magnetic resonance imaging (MRI) to detect metastases to liver, brain, and bone as a single examination in women with breast cancer. Seventeen patients with biopsy-proven breast cancer and suspected metastatic disease attending over a 12-month period referred for both conventional imaging and...

متن کامل

A systematic pipeline for the objective comparison of whole-brain spectroscopic MRI with histology in biopsy specimens from grade III glioma.

The diagnosis, prognosis, and management of patients with gliomas are largely dictated by the pathological analysis of tissue biopsied from a selected region within the lesion. However, due to the heterogeneous and infiltrative nature of gliomas, identifying the optimal region for biopsy with conventional magnetic resonance imaging (MRI) can be quite difficult. This is especially true for low g...

متن کامل

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 22 5  شماره 

صفحات  -

تاریخ انتشار 2001