Extraction of a Micra Transcatheter Pacing System: First-in-human experience

نویسندگان

  • Saima Karim
  • Medhat Abdelmessih
  • Mark Marieb
  • Eric Reiner
  • Eric Grubman
چکیده

Clinical trials investigating the safety and effectiveness of transcatheter leadless pacemakers in humans are ongoing. These devices offer the benefits of cardiac pacing with the potential for a significant decrease in many of the risks associated with conventional pacing systems, including hematoma formation, pneumothorax, lead-related complications, and vascular obstruction. Human evaluation of the Medtronic Micra Transcatheter Pacing System (Medtronic, Minneapolis, MN) began in 2013, and the device is currently undergoing clinical investigation. The devices are implanted via a femoral venous approach and use a novel tined system for fixation to the right ventricular endocardium. The pacemakers can be readily retrieved at the time of implantation, but no data exist regarding the ability to remove these devices in humans after the initial implantation procedure. We report the first successful extraction of a Micra Transcatheter Pacing System, 3 weeks after initial device implantation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treating an infected transcatheter pacemaker system via percutaneous extraction

Introduction One of the most feared complications of a traditional pacemaker system is cardiac implantable electronic device infection. In such cases, a complete removal of the entire system is recommended. With the advent of the leadless transcatheter pacemaker system (TPS), the weak link— namely, the pacing leads that contribute to this problem— can be ultimately eliminated. At least 2 major ...

متن کامل

Retrieval of Medtronic Micra Transcatheter Pacing System after tether removal.

We implanted a Medtronic Micra Transcatheter Pacing System (TPS) using standard technique, but after cutting the tether, a slight resistance was felt when the tether was pulled back. Subsequently, the electrical properties of the system were unacceptable. In order to retrieve the TPS, a 3 F snare with a 10–25 mm loop can be loaded into the delivery system. However, this snare was not available....

متن کامل

External electrical cardioversion of persistent atrial fibrillation in a patient with a Micra™ Transcatheter Pacing System

We report a case of a 85-year old woman with a preexisting Transcatheter Pacing System (TPS) (Micra™ VR, Fa. Medtronic, Inc., Minneapolis, MN, USA) undergoing several external electrical cardioversions (CV) for symptomatic persistent atrial fibrillation (persAF). Due to bradycardia in the setting of atrial fibrillation a right apical TPS implantation was performed earlier. Four weeks prior to p...

متن کامل

Early performance of a miniaturized leadless cardiac pacemaker: the Micra Transcatheter Pacing Study

AIMS Permanent cardiac pacing is the only effective treatment for symptomatic bradycardia, but complications associated with conventional transvenous pacing systems are commonly related to the pacing lead and pocket. We describe the early performance of a novel self-contained miniaturized pacemaker. METHODS AND RESULTS Patients having Class I or II indication for VVI pacing underwent implanta...

متن کامل

Miniaturized Transcatheter Leadless Pacemaker in a Patient with Double Mechanical Prosthesis

Case Report A 75-year-old female patient with a background of systemic arterial hypertension, chronic atrial fibrillation with an episode of peripheral arterial embolism in the right upper limb and rheumatic valve disease, underwent mitral and aortic valve replacement receiving two mechanical valve prosthesis in combination with left atrial appendage occlusion. Six months after surgery, pharmac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2016