Feasibility of in vivo measurement of carotid wall shear rate using spiral Fourier velocity encoded MRI.

نویسندگان

  • Joao L A Carvalho
  • Jon-Fredrik Nielsen
  • Krishna S Nayak
چکیده

Arterial wall shear stress is widely believed to influence the formation and growth of atherosclerotic plaque; however, there is currently no gold standard for its in vivo measurement. The use of phase contrast MRI has proved to be challenging due to partial-volume effects and inadequate signal-to-noise ratio at the high spatial resolutions that are required. This work evaluates the use of spiral Fourier velocity encoded MRI as a rapid method for assessing wall shear rate in the carotid arteries. Wall shear rate is calculated from velocity histograms in voxels spanning the blood/vessel wall interface, using a method developed by Frayne and Rutt (Magn Reson Med 1995;34:378-387). This study (i) demonstrates the accuracy of the velocity histograms measured by spiral Fourier velocity encoding in a pulsatile carotid flow phantom compared with high-resolution two-dimensional Fourier transform phase contrast, (ii) demonstrates the accuracy of Fourier velocity encoding-based shear rate measurements in a numerical phantom designed using a computational fluid dynamics simulation of carotid flow, and (iii) demonstrates in vivo measurement of regional wall shear rate and oscillatory shear index in the carotid arteries of healthy volunteers at 3 T.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo assessment of carotid wall shear rate using spiral Fourier velocity encoding

Introduction: Arterial wall shear stress is widely believed to influence the formation and growth of atherosclerotic plaque [1-3], however, there is currently no gold standard for its in vivo measurement. High-resolution phase contrast is impractical due to partial-volume effects, long scan times, and inadequate SNR. In 1995, Frayne and Rutt [4] proposed a novel method for non-invasively estima...

متن کامل

Kinematics parameter extraction of longitudinal movement of common carotid arterial wall in healthy and atherosclerotic subjects based on consecutive ultrasonic image processing

Introduction:In this study, a non-invasive method based on consecutive ultrasonic image processing is introduced to assess time rate changes of the carotid artery wall displacement, velocity and acceleration in the longitudinal direction. The application of these parameters to discriminate healthy and atherosclerotic arteries was evaluated. Methods:Longitudinal displacement rate of common ...

متن کامل

Hemodynamics of human carotid artery bifurcations: computational studies with models reconstructed from magnetic resonance imaging of normal subjects.

PURPOSE The precise role played by hemodynamics, particularly wall shear stress, in the development and progression of vascular disease remains unclear, in large part because of a lack of in vivo studies with humans. Although technical challenges remain for noninvasively imaging wall shear stresses in humans, vascular anatomy can be imaged with sufficiently high resolution to allow reconstructi...

متن کامل

In vivo velocity vector imaging and time-resolved strain rate measurements in the wall of blood vessels using MRI.

In this paper, we present a new approach for velocity vector imaging and time-resolved measurements of strain rates in the wall of human arteries using MRI and we prove its feasibility on two examples: in vitro on a phantom and in vivo on the carotid artery of a human subject. Results point out the promising potential of this approach for investigating the mechanics of arterial tissues in vivo.

متن کامل

Image-based carotid flow reconstruction: a comparison between MRI and ultrasound.

Atherosclerosis is a major cause of morbidity and mortality. Its apparent link with wall shear stress (WSS) has led to considerable interest in the in vivo estimation of WSS. Determining WSS by combining medical images with computational fluid dynamics (CFD) simulations can be performed both with magnetic resonance imaging (MRI) and three-dimensional ultrasound (3DUS). This study compares predi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 63 6  شماره 

صفحات  -

تاریخ انتشار 2010