Incident analysis of Bucheon LPG filling station pool fire and BLEVE.

نویسندگان

  • Kyoshik Park
  • M Sam Mannan
  • Young-Do Jo
  • Ji-Yoon Kim
  • Nir Keren
  • Yanjun Wang
چکیده

An LPG filling station incident in Korea has been studied. The direct cause of the incident was concluded to be faulty joining of the couplings of the hoses during the butane unloading process from a tank lorry into an underground storage tank. The faulty connection of a hose to the tank lorry resulted in a massive leak of gas followed by catastrophic explosions. The leaking source was verified by calculating the amount of released LPG and by analyzing captured photos recorded by the television news service. Two BLEVEs were also studied.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Consequences Modeling of the Akçagaz Accident through Land Use Planning (LUP) Approach

In the study, consequences analysis of Akçagaz LPG Facilities accident was conducted.  The consequences analysis, modeling studies were performed by the use of EFFECTS 10.0 Software over two liquefied gas LOC (Loss of Containment) scenarios. One of the scenarios was G1: Instantaneous release corresponding to BLEVE (Boiling Liquid Expanding Vapor Explosion) and the other was G2: Release in 1...

متن کامل

ارزیابی ریسک و مدل سازی پیامد ناشی از موج انفجار پدیده BLEVE مخزن کروی LPG در یک پالایش‌گاه

Introduction: Although human industrial activities are as a part of efforts to achieve greater prosperity, the risks related to these activities are also expanding. Hazard identification and risk assessment in the oil and gas industries are essential to reduce the frequency and severity of accidents and minimize damage to people and property before their occurrence. The aim of this study was to...

متن کامل

Insights from the Risk Analysis of a Nearby Propane Tank Farm

Due to the flammability and explosion characteristics of the propane vapor cloud, a nearby propane tank farm could possibly present a significant risk to the operation of nuclear power plants. Accidental releases of propane may occur in the propane supply pipeline, at the propane storage tanks, or on the propane transportation routes due to propane transport trailer truck accidents. Loss of con...

متن کامل

واکاوی پیامدهای آتش‌سوزی و انفجار مخازن استوانه‌ای ذخیره گاز مایع در یک صنعت منتخب نفت و گاز

Background and aims: Accidents happened as a result of LPG leakage emphasizes the importance of the consequence analysis of fire and explosion in LPG storage tanks. The purpose of this study is to analysis the consequences of fire and explosion in a cylindrical LPG storage tank in an oil and gas industry. Method: In this analytical study, four possible failure scenarios including 1...

متن کامل

Simulation of fire stations resources considering the downtime of machines: A case study

Considering the increasing growth of cities, population and urban fabric density, it seems necessary that emergency facilities and services such as fire stations are positioned optimally so that they can fulfill the demands well. The aim of this study is the optimization of equipment use in the fire stations, minimization the time to arrive at the incident through management of referral call to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of hazardous materials

دوره 137 1  شماره 

صفحات  -

تاریخ انتشار 2006