Noninvasive measurement of carboxyhemoglobin: how accurate is accurate enough?

نویسندگان

  • William H Maisel
  • Roger J Lewis
چکیده

Exposure to carbon monoxide (CO) is the leading cause of death by poisoning in industrialized countries. It accounts for hundreds of accidental deaths and thousands of intentional deaths annually in the United States. CO is a colorless, odorless gas that is easily absorbed through the lungs when inhaled. It competes with oxygen for binding to hemoglobin, but because hemoglobin has an affinity for CO that is 200 to 250 times greater than that for oxygen, CO poisoning leads to decreased hemoglobin oxygen-carrying capacity, impaired oxygen delivery, and tissue hypoxia. Although timely diagnosis and treatment of CO poisoning are critical, diagnosis based on clinical presentation alone is difficult because symptoms are often nonspecific and can mimic the flu or other viral illness. Definitive diagnosis therefore relies on measurement of increased carboxyhemoglobin levels, which have traditionally been performed on blood samples by using a spectrophotometer. Because of the need to screen many patients with low likelihood of clinically important CO poisoning to ensure that all truly poisoned patients are identified and, further, because of the occasional need to screen large numbers of patients in the setting of a possible mass exposure, a rapid noninvasive diagnostic method would be clinically useful. Although conventional oximeters are unable to distinguish carboxyhemoglobin from oxyhemoglobin and can mistakenly report a 100% oxygen saturation even in the presence of CO, the Rad-57 CO-Oximeter (Masimo Corporation, Irvine, CA) uses a noninvasive sensor to distinguish between oxygenated hemoglobin, deoxygenated hemoglobin, and carboxyhemoglobin. Data are obtained by passing various wavelengths of visible and infrared light through a capillary bed (typically the sensor is placed on a finger), taking advantage of the variable light absorption of the different hemoglobin species. Initial marketing clearance of the Rad-57 was granted by the Food and Drug Administration (FDA) in 2005 on the basis of company-submitted data comparing the noninvasive methodology with simultaneous invasive carboxyhemoglobin

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of noninvasive multiwave pulse oximetry compared with carboxyhemoglobin from blood gas analysis in unselected emergency department patients.

STUDY OBJECTIVE Accurate and timely diagnosis of carbon monoxide (CO) poisoning is difficult because of nonspecific symptoms. Multiwave pulse oximetry might facilitate the screening for occult poisoning by noninvasive measurement of carboxyhemoglobin (COHb), but its reliability is still unknown. We assess bias and precision of COHb oximetry compared with the criterion standard blood gas analysi...

متن کامل

Noninvasive measurement of carboxyhemoglobin levels for adjustment of diffusion capacity measured during pulmonary function testing.

BACKGROUND The diffusing capacity of the lungs for carbon monoxide (D(LCO)) is commonly measured during pulmonary function testing (PFT). Although adjustment of the measured D(LCO) for an elevated baseline carboxyhemoglobin level is recommended, carboxyhemoglobin is not routinely measured, which may reduce the accuracy of D(LCO) measurements. We sought to assess the utility of routine carboxyhe...

متن کامل

Anxiety disorders in patients with COPD.

partment patients. Respir Care 2013;57(2): 232-240. 2. Touger M, Birnbaum A, Wang J, Chou K, Pearson D, Bijur P. Performance of the RAD-57 pulse CO-oximeter compared with standard laboratory carboxyhemoglobin measurement. Ann Emerg Med 2010;56(4): 382-388. 3. Ruppel GL, Wilson HA, Gall VK, Hempkens JA. Multi-wavelength pulse oximeter is not suitable for adjusting DLCO measurements. Respir Care ...

متن کامل

Performanceof an Automated Six-Wavelength Measurement of HemoglobinDerivatives

A new instrument for spectrophotometric determination of oxygen saturation (S) and the fractions of carboxyhemoglobin (FHo) and methemoglobin (FHI), the Hemoximeter OSM3 (Radiometer), was tested by comparativemeasurements with a multiwavelength method. We found that it gave reliable results for freshly drawn samples from patients. When samples with artificially induced high proportions of HbCO ...

متن کامل

Noninvasive hemoglobin monitoring: how accurate is enough?

Evaluating the accuracy of medical devices has traditionally been a blend of statistical analyses, at times without contextualizing the clinical application. There have been a number of recent publications on the accuracy of a continuous noninvasive hemoglobin measurement device, the Masimo Radical-7 Pulse Co-oximeter, focusing on the traditional statistical metrics of bias and precision. In th...