Intra-examiner repeatability and agreement in accommodative response measurements.
نویسندگان
چکیده
PURPOSE Clinical measurement of the accommodative response (AR) identifies the focusing plane of a subject with respect to the accommodative target. To establish whether a significant change in AR has occurred, it is important to determine the repeatability of this measurement. This study had two aims: First, to determine the intraexaminer repeatability of AR measurements using four clinical methods: Nott retinoscopy, monocular estimate method (MEM) retinoscopy, binocular crossed cylinder test (BCC) and near autorefractometry. Second, to study the level of agreement between AR measurements obtained with the different methods. METHODS The AR of the right eye at one accommodative demand of 2.50 D (40 cm) was measured on two separate occasions in 61 visually normal subjects of mean age 19.7 years (range 18-32 years). The intraexaminer repeatability of the tests, and agreement between them, were estimated by the Bland-Altman method. We determined mean differences (MD) and the 95% limits of agreement [coefficient of repeatability (COR) and coefficient of agreement (COA)]. RESULTS Nott retinoscopy and BCC offered the best repeatability, showing the lowest MD and narrowest 95% interval of agreement (Nott: -0.10 +/- 0.66 D, BCC: -0.05 +/- 0.75 D). The 95% limits of agreement for the four techniques were similar (COA = +/- 0.92 to +/-1.00 D) yet clinically significant, according to the expected values of the AR. The two dynamic retinoscopy techniques (Nott and MEM) had a better agreement (COA = +/-0.64 D) although this COA must be interpreted in the context of the low MEM repeatability (COR = +/-0.98 D). CONCLUSIONS The best method of assessing AR was Nott retinoscopy. The BCC technique was also repeatable, and both are recommended as suitable methods for clinical use. Despite better agreement between MEM and Nott, agreement among the remaining methods was poor such that their interchangeable use in clinical practice is not recommended.
منابع مشابه
Comparison of three monocular methods for measuring accommodative stimulus–response curves
PURPOSE The aim was to evaluate the repeatability of dynamic measurement of the accommodative stimulus-response curve (ASRC) at three different dioptric speeds using a modified instrument and its agreement with two other methods. METHODS Twenty-nine adults (23.5 ± 2.0 years) were enrolled in the study. ASRC was measured monocularly using three methods: dynamic and static measurement using a m...
متن کاملEvaluation of speed, repeatability, and reproducibility of digital radiography with manual versus computer-assisted cephalometric analyses.
The aims of this study were to evaluate intra-examiner repeatability and inter-examiner reproducibility of landmarks using two cephalometric analysing techniques, manual and computerized, and to compare these for speed. One hundred lateral cephalometric radiographs were randomly selected and 11 angular and six linear parameters were traced and measured by two examiners using the manual method a...
متن کاملRepeatability and Reproducibility of Eight Macular Intra-Retinal Layer Thicknesses Determined by an Automated Segmentation Algorithm Using Two SD-OCT Instruments
PURPOSE To evaluate the repeatability, reproducibility, and agreement of thickness profile measurements of eight intra-retinal layers determined by an automated algorithm applied to optical coherence tomography (OCT) images from two different instruments. METHODS Twenty normal subjects (12 males, 8 females; 24 to 32 years old) were enrolled. Imaging was performed with a custom built ultra-hig...
متن کاملComparison of central corneal thickness measurements using optical low-coherence reflectometry, Fourier domain optical coherence tomography, and Scheimpflug camera.
PURPOSE To compare the results of central corneal thickness (CCT) measurements obtained using optical low-coherence reflectometry (OLCR), Fourier domain optical coherence tomography (FD-OCT), and a Scheimpflug camera (SC), combined with Placido corneal topography. METHODS A total of 25 healthy subjects were enrolled in the present study, and one eye of each subject was included. A detailed op...
متن کاملPrecision and Agreement of Corneal Power Measurements Obtained Using a New Corneal Topographer OphthaTOP
PURPOSE To evaluate repeatability and reproducibility of anterior corneal power measurements obtained with a new corneal topographer OphthaTOP (Hummel AG, Germany) and agreement with measurements by a rotating Scheimpflug camera (Pentacam HR, Oculus, Germany) and an automated keratometer (IOLMaster, Carl Zeiss Meditec, Germany). METHODS The right eyes of 79 healthy subjects were prospectively...