Inappropriate shocks from a subcutaneous implantable cardioverter-defibrillator due to oversensing during periods of rate-related bundle branch block

نویسندگان

  • Maria João Sousa
  • Tim Betts
چکیده

The subcutaneous implantable cardioverter-defibrillator (S-ICD) is a novel technology with proven efficacy in sudden cardiac death prevention; however, there is a lack of long-term safety data. We describe the case of a 55-year-old female patient implanted with an S-ICD due to idiopathic ventricular fibrillation, who subsequently presented with inappropriate shocks leading to ventricular fibrillation that was successfully terminated by another shock. Inappropriate shocks were due to intermittent T wave oversensing during periods of rate-dependent right bundle branch block. Assessment of the S-ICD electrograms during an exercise test allowed successful reprogramming of the device׳s sensing vector with no further events.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Oversensing of atrial fibrillatory waves in a subcutaneous implantable cardioverter-defibrillator

Introduction Implantable cardioverter-defibrillators (ICDs) have been shown to improve survival in patients with ischemic or nonischemic cardiomyopathy when used for primary and secondary prevention settings. The limitations of transvenous ICDs include postimplant adverse events, defibrillator lead failure, and inappropriate shocks for atrial tachyarrhythmias due to fast ventricular response ra...

متن کامل

Inappropriate shocks by subcutaneous implantable cardioverter-defibrillator due to T-wave oversensing in hyperkalemia leading to ventricular fibrillation

Introduction The implantable cardioverter-defibrillator (ICD) has reduced mortality in survivors of sudden cardiac arrest and patients at high risk of sudden cardiac death. This benefit comes at the cost of device-related complications, including those related to transvenous leads. The subcutaneous ICD (S-ICD) is an alternative to the conventional transvenous ICD (TV-ICD) system and has no tran...

متن کامل

Inappropriate shocks in a patient with a subcutaneous implantable cardioverter-defibrillator

The subcutaneous implantable cardioverter-defibrillator (ICD) is becoming more widespread. Approved by the Food and Drug Administration for use in the United Stated in 2012, the subcutaneous ICD is now being implanted for primary and secondary prevention of sudden cardiac death among individuals meeting conventional ICD implantation criteria but who do not have an indication for cardiac resynch...

متن کامل

A case of inappropriate implantable cardioverter defibrillator therapy induced by T-wave oversensing due to hyperkalemia.

There have been reports of hyperkalemia-induced T-wave oversensing in patients with implantable cardioverter defibrillators (ICDs). However, a comparison of T-wave amplitudes and morphologies between the surface 12-lead electrocardiogram (ECG) and ICD electrogram has not been reported. We present the case of a 70-year-old man who received inappropriate ICD shocks due to hyperkalemia-induced T-w...

متن کامل

Routine exercise testing could not predict T‐wave oversensing in a patient after a subcutaneous implantable cardioverter‐defibrillator implant

Subcutaneous implantable cardioverter-defibrillators (S-ICDs) are susceptible to T-wave oversensing (TWOS) caused by high rate-dependent QRS-T morphology changes. We experienced an inappropriate S-ICD shock due to TWOS, which could not be predicted by routine exercise testing. A newly available high-pass filter might be effective for avoiding this.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 33  شماره 

صفحات  -

تاریخ انتشار 2017