Magnetic Resonance Imaging of the Ear for Patient-Specific Reconstructive Surgery
نویسندگان
چکیده
INTRODUCTION Like a fingerprint, ear shape is a unique personal feature that should be reconstructed with a high fidelity during reconstructive surgery. Ear cartilage tissue engineering (TE) advantageously offers the possibility to use novel 3D manufacturing techniques to reconstruct the ear, thus allowing for a detailed auricular shape. However it also requires detailed patient-specific images of the 3D cartilage structures of the patient's intact contralateral ear (if available). Therefore the aim of this study was to develop and evaluate an imaging strategy for acquiring patient-specific ear cartilage shape, with sufficient precision and accuracy for use in a clinical setting. METHODS AND MATERIALS Magnetic resonance imaging (MRI) was performed on 14 volunteer and six cadaveric auricles and manually segmented. Reproducibility of cartilage volume (Cg.V), surface (Cg.S) and thickness (Cg.Th) was assessed, to determine whether raters could repeatedly define the same volume of interest. Additionally, six cadaveric auricles were harvested, scanned and segmented using the same procedure, then dissected and scanned using high resolution micro-CT. Correlation between MR and micro-CT measurements was assessed to determine accuracy. RESULTS Good inter- and intra-rater reproducibility was observed (precision errors <4% for Cg.S and <9% for Cg.V and Cg.Th). Intraclass correlations were good for Cg.V and Cg.S (>0.82), but low for Cg.Th (<0.23) due to similar average Cg.Th between patients. However Pearson's coefficients showed that the ability to detect local cartilage shape variations is unaffected. Good correlation between clinical MRI and micro-CT (r>0.95) demonstrated high accuracy. DISCUSSION AND CONCLUSION This study demonstrated that precision and accuracy of the proposed method was high enough to detect patient-specific variation in ear cartilage geometry. The present study provides a clinical strategy to access the necessary information required for the production of 3D ear scaffolds for TE purposes, including detailed patient-specific shape. Furthermore, the protocol is applicable in daily clinical practice with existing infrastructure.
منابع مشابه
Are magnetic resonance imaging or radiographic findings correlated with clinical prognosis in spinal cord neuropathy?
Dogs presented to the Small Animal Hospital of Veterinary Medicine, University of Tehran were included in the present study if spinal or intervertebral disc involvement was suspected. Clinical signs were recorded as well as general information of the patient such as age, breed and sex. Sixty dogs were examined radiographically and two standard orthogonal lateral and ventrodorsal projections wer...
متن کاملMagnetic Resonance Imaging Assessment of Hip Abductor after Total Hip Arthroplasty Using a Direct Lateral Approach
Background: Surgical techniques and rehabilitations after total hip arthroplasty (THA) play a significant role in theimprovement of pain and limping. This study aimed to assess hip abductor muscle’s diameter and its strength after 6months postoperative THA performed by Hardinge approach.Methods: After obtaining the patients’ demographic characteristics, the preoperative values...
متن کاملSimultaneous Contralateral Vestibular Schwannoma and Glomus Tumor of the Temporal Bone- A Case Report
Introduction: Presence of vestibular schwannoma and a simultaneous glomus jugulare tumor is an extremely rare event. There is only one case report regarding the incidence of a contralateral vestibular schwannoma, along with a glomus jugulare tumor. Herein, we present the second case with a contralateral tumor. Case Report: A 69-year-old woman presented with a long hist...
متن کاملAssessment of Organ Specific Iron Overload in Transfusion-dependent Thalassemia by Magnetic Resonance Imaging Techniques
The consequence of repeated blood transfusions in thalassemia is iron overload in different organs. Magnetic resonance imaging (MRI) is a reliable, non-invasive and accurate method for iron detection in various tissues, hence the introduction of MRI has revolutionized the management of these patients and improved the life expectancy of them. Cardiac MRI T2* has a profound effect not only on est...
متن کاملI-59: Diagnostic Accuracy of Physical Examination,Transvaginal Sonography, RectalEndoscopic Sonography, and Magnetic ResonanceImaging to Diagnose Deep InfiltratingEndometriosis
Background: To compare the value of physical examination, transvaginal sonography (TVS), rectal endoscopic sonography (RES), and magnetic resonance imaging (MRI) for the assessment of different locations of deep infiltrating endometriosis (DIE). Materials and Methods: Ninety-two consecutive patients with clinical evidence of pelvic endometriosis. Physical examination, TVS, RES, and MRI, perform...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2014