Sensitivity and specificity of high-resolution balanced steady-state free precession fMRI at high field of 9.4 T

نویسندگان

  • Sung-Hong Park
  • Tae Kim
  • Ping Wang
  • Seong-Gi Kim
چکیده

Balanced steady-state free precession (bSSFP) is an attractive fMRI method at high fields due to minimal spatial distortion. To examine sensitivity and specificity of bSSFP fMRI at ultrahigh magnetic field of 9.4T, we performed high-resolution pass-band high flip-angle (16°) bSSFP fMRI with four phase cycling (PC) angles at two repetition times (TR) of 10ms and 20ms and conventional gradient-recalled-echo (GRE) fMRI with TR of 20ms on rat brain during forepaw stimulation. The sensitivity of bSSFP fMRI with TR of 20ms was higher than that of GRE fMRI regardless of PC angle. Because of magnetic field inhomogeneity, fMRI foci were changed with PC angle in bSSFP fMRI, which was more prominent when TR was shorter. Within a middle cortical layer region where magnetic field inhomogeneity was relatively small, the homogeneity of bSSFP fMRI signals was higher at shorter TR. Acquisition of baseline transition-band bSSFP images helped to identify pass- and transition-band regions and to understand corresponding bSSFP fMRI signals. Fourier analysis of the multiple PC bSSFP datasets provided echoes of multiple pathways separately, and the main echo component showed lower sensitivity and better homogeneity than the free induction decay component. In summary, pass-band bSSFP techniques would have advantages over GRE-based fMRI in terms of sensitivity, and may be a good choice for fMRI at ultrahigh fields.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compressed Sensing for fMRI: Feasibility Study on the Acceleration of Non-EPI fMRI at 9.4T

Conventional functional magnetic resonance imaging (fMRI) technique known as gradient-recalled echo (GRE) echo-planar imaging (EPI) is sensitive to image distortion and degradation caused by local magnetic field inhomogeneity at high magnetic fields. Non-EPI sequences such as spoiled gradient echo and balanced steady-state free precession (bSSFP) have been proposed as an alternative high-resolu...

متن کامل

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

T2-weighted BOLD fMRI at 9.4 T using a S2-SSFP-EPI sequence

Introduction: It has been hypothesized that T2-weighted BOLD fMRI at ultra-high field shows higher spatial specificity than T2*weighted BOLD, since the main signal contribution is expected to come from the extravascular spins of the microvasculature [1-3]. Unfortunately, the number of slices that can be acquired in multi-slice SE-EPI is often highly limited at ultra-high field due to SAR constr...

متن کامل

T2- and T2*-weighted High-resolution Fmri at 7t Using Non-balanced Ssfp

Introduction Non-balanced Steady-state free precession (nb-SSFP) has been proposed as an alternative sequence for T2-weighted BOLD fMRI at high field strength [1]. nb-SSFP is attractive because of low rf power deposition and low image distortion, and the possibility of acquiring the T2-weighted S2 signal together with the T2*-weighted S1 signal resembling SE and GE signal characteristics respec...

متن کامل

Resting-State fMRI Using Passband Balanced Steady-State Free Precession

OBJECTIVE Resting-state functional MRI (rsfMRI) has been increasingly used for understanding brain functional architecture. To date, most rsfMRI studies have exploited blood oxygenation level-dependent (BOLD) contrast using gradient-echo (GE) echo planar imaging (EPI), which can suffer from image distortion and signal dropout due to magnetic susceptibility and inherent long echo time. In this s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • NeuroImage

دوره 58 1  شماره 

صفحات  -

تاریخ انتشار 2011