Stomach and duodenum: radiographic magnification using computed radiography (CR).

نویسندگان

  • Y Nakano
  • K Togashi
  • K Nishimura
  • K Itoh
  • I Fujisawa
  • R Asato
  • H Adachi
  • H Itoh
  • K Torizuka
چکیده

We performed direct radiographic magnification (X3) using a 0.1-mm microfocal tube and computed radiography (CR) in air-barium double-contrast studies of the stomach and duodenum. To eliminate blurring of the image due to motion, we used the maximum kilovolt peak rate possible (102 kVp), the maximum milliampere second rate possible (64 mAs), the shortest possible exposure time (0.1 second), and a horizontal x-ray beam. With the patients in the supine position, CR provided the wide image reproduction range required to obtain satisfactory radiographs. Image processing in the CR system produced radiographs with increased radiographic contrast and enhanced edge definition of anatomic borders or pathologic processes. The duodenal villi were clearly visible in 45% of the cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality comparison of direct digital panoramic radiography and computed radiography panoramic

BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...

متن کامل

Artefacts found in computed radiography.

Artefacts on radiographic images are distracting and may compromise accurate diagnosis. Although most artefacts that occur in conventional radiography have become familiar, computed radiography (CR) systems produce artefacts that differ from those found in conventional radiography. We have encountered a variety of artefacts in CR images that were produced from four different models plate reader...

متن کامل

Practical Evaluation of Image Quality in Computed Radiographic (CR) Imaging Systems

A number of complementary metrics are available to assess the performance of digital X-ray imaging systems. However, the sensitivity of these metrics to changes in the electro-optical imaging chain is poorly understood. Some of the commonly used metrics include Contrast to Noise ratio (CNR), limiting spatial resolution, Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and the Dete...

متن کامل

بررسی بزرگنمایی عمودی رادیوگرافی پانورامیک توسط مقاطع CT اسکن تهیه شده برای ایمپلنت

Background and Aims: The Panoramic radiography is one of the routine techniques in implant imaging. Although there are some limitations with this technique, panoramic radiography is radiographic choice for basic evaluation for implant treatment. Many studies have been designed to determine magnification in panoramic images but most of them were performed on dry skulls or radiographic phantoms. ...

متن کامل

Optimization of Dose and Image Quality in Full-fiand Computed Radiography Systems for Common Digital Radiographic Examinations

IntroductionA fine balance of image quality and radiation dose can be achieved by optimization to minimize stochastic and deterministic effects. This study aimed in ensuring that images of acceptable quality for common radiographic examinations in digital imaging were produced without causing harmful effects. Materials and MethodsThe study was conducted in three phases. The pre-optimization inv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 160 2  شماره 

صفحات  -

تاریخ انتشار 1986