Simulation of a suite of generic long-pulse neutron instruments to optimize the time structure of the ESS

نویسندگان

  • Kim Lefmann
  • Kaspar H. Klenø
  • Jonas Okkels Birk
  • Britt R. Hansen
  • Sonja L. Holm
  • Erik Knudsen
  • Klaus Lieutenant
  • Lars von Moos
  • Morten Sales
  • Peter K. Willendrup
  • Ken H. Andersen
چکیده

to optimize the time structure of the ESS Kim Lefmann, 2 Kaspar H. Klenø, 2 Jonas Okkels Birk, 2, 3 Britt R. Hansen, 5 Sonja L. Holm, 2 Erik Knudsen, 5 Klaus Lieutenant, 7, 8 Lars von Moos, 5, 10 Morten Sales, 2 Peter K. Willendrup, 5 and Ken H. Andersen Nanoscience and eScience Centers, Niels Bohr Institute, University of Copenhagen, Universitetsparken 5, 2100 Copenhagen Ø, Denmark Danish Workpackage for the ESS Design Update Phase, Universitetsparken 5, 2100 Copenhagen Ø, Denmark Laboratory for Quantum Magnetism, École Polytecnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland Institute of Physics, Technical University of Denmark, 2800 Lyngby, Denmark Danish Workpackage for the ESS Design Update Phase, 2800 Lyngby, Denmark Institute for Energy Technology, Instituttveien 18, 2007 Kjeller, Norway Helmholtz Center for Energy and Materials, Hahn-Meitner Platz, 14109 Berlin, Germany German Work Package for the ESS Design Update, Hahn-Meitner Platz, 14109 Berlin, Germany Department of Energy Conversion and Storage, Technical University of Denmark, 4000 Roskilde, Denmark Institute for Energy Conversion, Technical University of Denmark, 4000 Roskilde, Denmark European Spallation Source ESS AB, 22100 Lund, Sweden

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An analytical model based on simulation aiming to improve patient flow in a hospital surgical suite

Surgical suits allocate a large amount of expenses to hospitals; on the other hand, they constitute a huge part of hospital revenues. Patient flow optimization in a surgical suite by omitting or reducing bottlenecks which cause loss of time is one of the key solutions in minimizing the patients’ length of stay[1] (LOS) in the system, lowering the expenses, increasing efficiency, and also enhanc...

متن کامل

Modeling the measurement of VVER-1000 reactor power by neutron and gamma radiation with MCNP code

The present study deals with a new method for measuring the power of a reactor. This method uses gamma and neutron radiation resulted from the entire reactor structure, without changing its structure (online). In terms of functionality, this method can measure the reactor power in real-time and report it instantly. In order to obtain the relationship between reactor power and gamma and neutron ...

متن کامل

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

Optimum neutron energy simulation in treatment of head and neck cancer at different depths in the BNCT method

Introduction: Recently head and neck cancer has pay attention to many researchers. Its therapeutic methods include surgery, chemotherapy, radiotherapy and Boron neutron capture therapy (BNCT). BNCT is better than conventional radiotherapy because it targets the tumor cell. This method involves two steps of infusion of stable 10B and then neutron radiation with a suitable intens...

متن کامل

The safety of a landmine detection system using graphite and polyethylene moderator

Background: Several landmine detection methods, based on nuclear techniques, have been suggested up to now. Neutron-induced gamma emission, neutron and gamma attenuation, and fast neutron backscattering are the nuclear methods used for landmine detection. In this paper an optimized (safe and effective) moderating structure using an 241Am-Be neutron source for detecting landmines has been invest...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013