Positioning errors and efficiency in fiber spectrographs
نویسنده
چکیده
The use of wide-field multi-object fiber-input spectrographs for large redshift surveys introduces the possibility of variations in the observed signal-to-noise ratio across the survey area due to errors in positioning the fibers with respect to the target image positions, leading to position-dependent errors in the survey catalog. This paper brings together a comprehensive description of the sources of fiber-to-image position errors in different instrument designs, and quantifies their effects on the efficiency with which signal is recorded. For point sources, a function relating a fractional efficiency and an equivalent aperture correction to the fiber-to-image position error, the fiber diameter and the image size is plotted for typical values of fiber and image sizes found in current instruments. The tools required by observers to maximize the efficiency of fiber-spectrographic surveys are discussed. Subject headings: instrumentation: spectrographs — techniques: spectroscopic — surveys — astrometry
منابع مشابه
Astrometric demands of fibre-input spectrographs for wide-field quasar redshift surveys
A potential problem with using wide-field multi-object spectrographs for quasar redshift surveys is the introduction of positiondependent selection effects into the survey catalogue because of variations in the observed signal-to-noise ratio (SNR) across the survey area. A function relating signal losses in instruments using optical fibre input to the fibre-to-image position error, the fibre di...
متن کاملImprovement in Differential GPS Accuracy using Kalman Filter
Global Positioning System (GPS) is proven to be an accurate positioning sensor. However, there are several sources of errors such as ionosphere and troposphere effects, satellite time errors, errors of orbit data, receivers errors, and errors resulting from multi-path effect which reduce the accuracy of low-cost GPS receivers. These sources of errors also limit the use of single-frequency GPS r...
متن کاملCommon Positioning Errors in Digital Panoramic Radiographies Taken In Mashhad Dental School
Introduction: The present study was aimed at evaluating common positioning errors on panoramic radiographs taken in the Radiology Department of Mashhad Dental School. Materials and methods: The study sample included 1,990 digital panoramic radiographs taken in the Radiology Department of Mashhad Dental School by a Planmeca Promax (Planmeca Oy, Helsinki, Finland), during a 2-year period (2010–20...
متن کامل‘modal-noise’ in Single-mode Fibers: a Cautionary Note for High Precision Radial Velocity Instruments
Exploring the use of single-mode fibers (SMFs) in high precision Doppler spectrometers has become increasingly attractive since the advent of diffraction-limited adaptive optics systems on largeaperture telescopes. Spectrometers fed with these fibers can be made significantly smaller than typical ‘seeing-limited’ instruments, greatly reducing cost and overall complexity. Importantly, classical ...
متن کاملEvaluation of Six-Dimensional Cranial Target Positioning Accuracy in Two Different Immobilization Methods Using Exactrac System
Introduction: The aim of this study was to determine the accuracy of two different immobilization methods in patient positioning in cranial radiotherapy. The six-dimensional (6D) target localization accuracy of using a dedicated stereotactic mask was compared with that of a conventional head mask by the ExacTrac system. Material and Methods: ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002