Critical assessment of the elemental composition of Corning archeological reference glasses by LA-ICP-MS

نویسندگان

  • B. Wagner
  • A. Nowak
  • E. Bulska
  • K. Hametner
  • D. Günther
چکیده

Corning archeological reference glasses A, B, C, and D have been made to simulate different historic technologies of glass production and are used as standards in historic glass investigations. In this work, nanoseconds (193, 266 nm) and femtosecond (800 nm) laser ablation were used to study the elemental composition of Corning glasses using laser ablation inductively coupled plasma mass spectrometry. The determined concentrations of 26 oxides (Li(2)O, B(2)O(3), Na(2)O, MgO, Al(2)O(3), SiO(2), P(2)O(5), K(2)O, CaO, TiO(2), V(2)O(5), Cr(2)O(3), MnO, Fe(2)O(3), CoO, NiO, CuO, ZnO, Rb(2)O, SrO, ZrO(2), SnO(2), Sb(2)O(5), BaO, PbO, Bi(2)O(3)) are compared with values reported in the literature. Results show variable discrepancies between the data, with the largest differences found for Cr(2)O(3) in Corning A; Li(2)O, B(2)O(3), and Cr(2)O(3) in Corning B; and MnO, Sb(2)O(5), Cr(2)O(3), and Bi(2)O(3) in Corning C. The best agreement between the measured and literature values was found for Corning D. However, even for this reference, glass re-evaluation of the data was necessary and new values for PbO, BaO, and Bi(2)O(3) are proposed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microbeam Characterization of Corning Archeological Reference Glasses: New Additions to the Smithsonian Microbeam Standard Collection

An initial study of the minor element, trace element, and impurities in Corning archeological references glasses have been performed using three microbeam techniques: electron probe microanalysis (EPMA), laser ablation ICP-mass spectrometry (LA ICP-MS), and secondary ion mass spectrometry (SIMS). The EPMA results suggest a significant level of heterogeneity for a number of metals. Conversely, h...

متن کامل

بررسی ترکیب و نقش عناصر کمیاب در شکل‌گیری کانسنگ مگنتیتی توده نفوذی نامن، غرب سبزوار به روش LA-ICP-MS

Basic rocks appear as cumulative hornblende gabbros in the Namen pluton, West of Sabzevar. One outcrop of these rocks contains magnetite ore patches. Although magnetite- bearing hornblende gabbro (MHG) and other hornblende gabbros (HG) have similar mineralogy, their trace element compositions are completely different. Trace element analysis of magnetite minerals by laser ablation inductively co...

متن کامل

Major- and Trace-element Analysis of Sulfide Ores by Laser-ablation Icp–ms, Solution Icp–ms, and Xrf: New Data on International Reference Materials

International reference materials representing a diverse suite of sulfide ores and related lithologies have been analyzed for major and trace element concentrations by XRF, solution ICP–MS, and laser-ablation ICP–MS (LA–ICP–MS) after fusion of the sample to a lithium borate glass. Reference materials analyzed for this study include a wide variety of bulk compositions, including ores of Pb–Zn su...

متن کامل

A New Basaltic Glass Microanalytical Reference Material for Multiple Techniques

Introduction The U.S. Geological Survey (USGS) has been producing reference materials since the 1950s [1]. Over 50 materials have been developed to cover bulk rock, sediment, and soils for the geological community. These materials are used globally in geochemistry, environmental, and analytical laboratories that perform bulk chemistry and/or microanalysis for instrument calibration and quality ...

متن کامل

Forensic discrimination of sheet glass exposed to high temperature by the determination of trace impurities using ICP-MS.

The effect of heating on the refractive index (RI) and trace elemental compositions of glass was investigated in order to develop an accurate discrimination method of glass fragments exposed to the high temperature of fire on illegal entrance into a crime scene for robbery. Fragments taken from 5 different sheet glasses were subjected to RI measurement and analysis of trace elements using ICP-M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 402  شماره 

صفحات  -

تاریخ انتشار 2012