A randomized crossover study comparing a novel needle guidance technology for simulated internal jugular vein cannulation.
نویسندگان
چکیده
BACKGROUND Despite ultrasound guidance for central line placement, complications persist, as exact needle location is often difficult to confirm with standard two-dimension ultrasound. A novel real-time needle guidance technology has recently become available (eZono, Germany) that tracks the needle during insertion. This randomized, blinded, crossover study examined whether this needle guidance technology improved cannulation of a simulated internal jugular (IJ) vein in an ultrasound phantom. METHODS One hundred physicians were randomized to place a standard needle in an ultrasound neck phantom with or without the needle guidance system. Video cameras were placed externally and within the lumens of the vessels to record needle location in real time. The primary outcome measured was the rate of posterior wall puncture. Secondary outcomes included number of carotid artery punctures, number of needle passes, final needle position, time to cannulation, and comfort level with this new technology. RESULTS The incidence of posterior vessel wall puncture without and with needle guidance was 49 and 13%, respectively (P < 0.001, odds ratio [OR] = 7.33 [3.44 to 15.61]). The rate of carotid artery puncture was higher without needle navigation technology than with needle navigation 21 versus 2%, respectively (P = 0.001, OR = 12.97 [2.89 to 58.18]). Final needle tip position being located within the lumen of the IJ was 97% accurate with the navigation technology and 76% accurate with standard ultrasound (P < 0.001, OR = 10.42 [2.76 to 40.0]). Average time for successful vessel cannulation was 1.37 times longer without guidance technology. CONCLUSION This real-time needle guidance technology (eZono) shows significant improvement in needle accuracy and cannulation time during simulated IJ vein puncture.
منابع مشابه
A New Biplane Ultrasound Probe for Real-Time Visualization and Cannulation of the Internal Jugular Vein
Ultrasound guidance is recommended for cannulation of the internal jugular vein. Use of ultrasound allows you to identify relevant anatomy and possible anatomical anomalies. The most common approach is performed while visualizing the vein transversely and inserting the needle out of plane to the probe. With this approach needle tip visualization may be difficult. We report the use of a new bipl...
متن کاملAn unseen danger: frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance.
OBJECTIVES To evaluate the frequency of unsuspected posterior vessel wall penetration of the internal jugular vein during ultrasound-guided needle cannulation. DESIGN Prospective, single-blinded observational study. SETTING Urban level I emergency department with an annual census of 80,000. PATIENTS Residents who had previously completed a 2-day ultrasound course including a 3-hr didactic...
متن کاملAccidental arterial puncture during right internal jugular vein cannulation in cardiac surgical patients
BACKGROUND The primary aim of this study was to compare the incidence of accidental arterial puncture during right internal jugular vein (RIJV) cannulation with and without ultrasound guidance (USG). The secondary end points were to assess if USG improves the chances of successful first pass cannulation and if BMI has an impact on incidence of arterial puncture and the number of attempts that a...
متن کاملLong versus short axis ultrasound guided approach for internal jugular vein cannulation: a prospective randomised controlled trial.
AIM The aim of this study was to compare the short and long axis approaches to ultrasound guided right internal jugular vein cannulation with respect to indicators of success. METHODS Patients undergoing cardiac surgery requiring central venous cannulation (99 patients) were randomised to undergo either long or short axis ultrasound guided cannulation of the right internal jugular vein by a s...
متن کاملUltrasonic locating devices for central venous cannulation: meta-analysis.
OBJECTIVES To assess the evidence for the clinical effectiveness of ultrasound guided central venous cannulation. DATA SOURCES 15 electronic bibliographic databases, covering biomedical, science, social science, health economics, and grey literature. DESIGN Systematic review and meta-analysis of randomised controlled trials. Populations Patients scheduled for central venous access. INTERVEN...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Anesthesiology
دوره 123 3 شماره
صفحات -
تاریخ انتشار 2015