Vertebral augmentation of osteoporotic and malignant compression fractures: our viewpoint and experience in preventing cement leakage.

نویسندگان

  • Zhao Huan
  • Qin Shi
  • Sun Zhi-Yong
  • Zhang Ning
  • Yin Guo-Yong
  • Huilin Yang
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous Vertebroplasty in Iranian Patients with Osteoporotic Vertebral Fractures

Background: Osteoporotic compression vertebral fractures are common clinical problems. In those with refractory fractures, percutaneous cement augmentation has been suggested. The aim of this study was to evaluate the functional outcome of percutaneous vertebroplasty in Iranian patients with refractory osteoporotic fractures. Methods: We retrospectively studied 37 osteoporotic fractures in 28 p...

متن کامل

Feasibility, safety and cement leakage in vertebroplasty of osteoporotic and malignant compression fractures using ultra-viscous cement and hydraulic delivery system.

BACKGROUND The major complications arising from vertebroplasty or kyphoplasty are related to leakage of cement beyond the confines of the collapsed vertebral body. Traditionally, a liquid (low viscosity) cement is used in most vertebroplasty systems available on the market, coupled with mechanical injection devices or one mL syringes. OBJECTIVES The purpose of this study is to evaluate the fe...

متن کامل

Initial clinical experience with a novel vertebral augmentation system for treatment of symptomatic vertebral compression fractures: A case series of 26 consecutive patients

BACKGROUND Minimally invasive vertebral augmentation procedures are widely used to treat vertebral compression fractures although procedural polymethylmethacrylate cement leakage remains common. We report herein our initial experience with a novel vertebral augmentation technique designed to treat symptomatic vertebral osteoporotic fractures and osteolytic metastases with minimal cement extrava...

متن کامل

Osseofix® System for Percutaneous Stabilization of Osteoporotic and Tumorous Vertebral Compression Fractures – Clinical and Radiological Results After 12 Months Minimalinvasive perkutane Stabilisierung osteoporotischer und tumoröser Wirbelkörperfrakturen mit dem Osseofix®-System – klinische und radiologische Ergebnisse nach 12 Monaten

Purpose: Determining whether implantation of an expandable titanium mesh cage (Osseofix® system) is a successful and safeminimally invasive therapy for osteoporotic and tumorous vertebral compression fractures (VCFs). Materials and Methods: 32 patients (25 women, 7 men, mean age 71) with 46 osteoporotic or tumorous VCFs (T6 to L4) from June 2010 to January 2012 were included. All of them were s...

متن کامل

Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures.

STUDY DESIGN An Institutional Review Board-approved Phase I efficacy study of inflatable bone tamp usage in the treatment of symptomatic osteoporotic compression fractures. OBJECTIVES To evaluate the safety and efficacy of inflatable bone tamp reduction and cement augmentation, "kyphoplasty," in the treatment of painful osteoporotic vertebral compression fractures. SUMMARY OF BACKGROUND DAT...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Pain physician

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2012