High incidence of pacemaker syndrome in patients with sinus node dysfunction treated with ventricular-based pacing in the Mode Selection Trial (MOST).
نویسندگان
چکیده
OBJECTIVES We evaluated the incidence, predictors, and treatment of pacemaker syndrome in patients with sinus node dysfunction treated with ventricular-based (VVIR) pacing in the Mode Selection Trial (MOST). BACKGROUND Pacemaker syndrome, or intolerance to VVIR pacing, consists of cardiovascular signs and symptoms induced by VVIR pacing. METHODS The definition of pacemaker syndrome required that a patient with single-chamber VVIR pacing develop either congestive signs and symptoms associated with retrograde conduction during VVIR pacing or a >or=20 mm Hg reduction of systolic blood pressure during VVIR pacing, associated with reproducible symptoms of weakness, lightheadedness, or syncope. RESULTS Of 996 patients randomized to VVIR pacing, 182 (18.3%) met criteria for pacemaker syndrome in follow-up. Pacemaker syndrome occurred early in most patients (13.8% at 6 months, 16.0% at 1 year, increasing to 19.7% at 4 years). Baseline univariate predictors of pacemaker syndrome included a lower sinus rate and higher programmed pacemaker rate. Previous heart failure, ejection fraction, and drop in systolic blood pressure with VVIR pacing at implantation did not predict the development of pacemaker syndrome. Post-implantation predictors of pacemaker syndrome were a higher percentage of paced beats, higher programmed low rate, and slower underlying spontaneous sinus rate. Quality of life decreased at the time of diagnosis of pacemaker syndrome and improved with reprogramming to atrial-based pacing. CONCLUSIONS Severe pacemaker syndrome developed in nearly 20% of VVIR-paced patients and improved with reprogramming to the dual-chamber pacing mode. Because prediction of pacemaker syndrome is difficult, the only way to prevent pacemaker syndrome is to implant atrial-based pacemakers in all patients.
منابع مشابه
Single-lead ventricular pacing is no longer an option for sick sinus syndrome.
n this issue of the Journal, Link et al. (1) report a study on he occurrence of pacemaker syndrome in the Mode Selecion (MOST) trial. The MOST trial is the largest randomzed trial of pacing mode selection in patients with sick sinus yndrome (SSS), including a total of 2,010 patients who all eceived rate-adaptive atrioventricular synchronous dualhamber pacing (DDDR) pacemakers and were randomly ...
متن کاملAssociation of prolonged QRS duration with death in a clinical trial of pacemaker therapy for sinus node dysfunction.
BACKGROUND Prolonged QRS duration (QRSd) is an important prognostic indicator for death and heart failure hospitalization in patients with systolic heart failure. The relationship of baseline QRSd to death and heart failure hospitalization in patients with sinus node dysfunction who require pacemaker therapy is unknown. METHODS AND RESULTS Baseline QRSd from 12-lead ECGs before pacemaker impl...
متن کاملPacemaker Twiddler's Syndrome
A 76-yr-old man with unipolar ventricular pacemaker, previously implanted in the right ventricular apex, presented with syncopal attack and twitching of the right pectoralis muscle. He finally was diagnosed as having Twiddler's syndrome. The patient had a pulse rate of 36/min and cannon waves in the neck veins. Chest radiography showed a dislodged pacing lead completely wrapped around the pulse...
متن کاملPermanent pacing: new indications.
ver the past 40 years, permanent pacemakers have become standard treatment for patients with symptomatic sinus node disease and documented, or suspected, high grade atrioventricular (AV) block. Permanent pacemakers were first developed for the treatment of heart block, often in young patients following surgical repair of congenital heart defects. These early pacemakers were primitive devices, a...
متن کامل[Clinical safety and efficacy of single-chamber atrial pacing in sick sinus syndrome: long-term follow-up].
INTRODUCTION AND OBJECTIVES Although atrial pacing is a more physiological mode of stimulation in sinus node dysfunction, the pacing modes most often are used DDD and VVI. The aim of our study was to demonstrate that AAI/AAIR pacing is effective and safe by analyzing the complications and mortality of this pacing mode in a long-term follow-up study. PATIENTS AND METHOD Between 1982 and 2000 d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American College of Cardiology
دوره 43 11 شماره
صفحات -
تاریخ انتشار 2004