Static and dynamic operating characteristics of a pericardial balloon.

نویسندگان

  • D R Hamilton
  • G Devries
  • J V Tyberg
چکیده

Previously, we developed a balloon transducer to measure the constraint of the pericardium (i.e., pericardial pressure) on the surface of the heart. It was validated physiologically in that it was shown to measure a pressure equal to the difference between the left ventricular end-diastolic pressure measured before and after pericardiectomy at the same left ventricular volume. To define its static operating characteristics, we loaded the balloon nonuniformly with weights that covered fractions of the balloon surface and found that the balloon accurately recorded the average stress if the stress was applied over at least 23% of its surface. To test its performance when curved, we placed it in large and small cylinders (minimum diameter 31 mm) and found that the balloon accurately recorded the stress. To define its dynamic operating characteristics, we applied sinusoidal stresses and found that its frequency response was limited only by that of the connecting catheter. When better dynamic response is required, we introduce a micromanometer-tipped catheter to obtain a unity-gain frequency response that is flat to 200 Hz.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between Static and Dynamic Balance Characteristics with Types of MS in Women

MS is a lifelong disease that could involve the person in different forms. Knowing balance characteristics of different types of this chronic disease helps the specialists for controlling their complications. The purpose of this study was to recognize static and dynamic balance of different type of MS and to compare MS patients with healthy individual. 54 MS women in three groups (27- Relapsing...

متن کامل

Influence of Operation Conditions Upon the Dynamic Steady State Performance of Switched Reluctance Motor

In order to obtain more accurate predicted dynamic steady-state performance with shorter computation time, an available mathematical model is modified and presented. Using this modified model, performance of a typical switched reluctance motor (SRM) under a wide range of variations of operating conditions is obtained and discussed. These include variations of speed, voltage, load and switching ...

متن کامل

A COMPARATIVE STUDY ON CHARACTERISTICS OF DYNAMIC OXIDE FILM OF MOLTEN Zn-Al ALLOYS

This paper investigates the difference between thickness of zinc-based alloys oxide films in dynamic condition using the oxide-metal-oxide (OMO) sandwich method and static condition by theoretical calculations. In dynamic condition, the thickness of the oxide film in the OMO sandwich sample was characterized by scanning electron microscopy (SEM). In the static condition, the thickness and type ...

متن کامل

Percutaneous balloon pericardiotomy as the initial and definitive treatment for malignant pericardial effusion.

INTRODUCTION AND OBJECTIVES Malignant pericardial effusion has a high recurrence rate after pericardiocentesis. We sought to confirm the efficacy of percutaneous balloon pericardiotomy as the initial treatment of choice for these effusions. METHODS Retrospective analysis of the clinical, echocardiographic, and follow-up characteristics of a consecutive series of percutaneous balloon pericardi...

متن کامل

Relationship between somatotype and static, semi-dynamic and dynamic postural control in adolescent, young and middle-aged women

Objective: Somatotype is a method to describe the human physique which can influence postural control. The aim of this study was the relationship between somatotype and static, semi-dynamic and dynamic postural control. Methods: 140 females 12-50-year-old(26.45±10.94) participated in this study who had no skeletal, vestibular and neurological abnormalities and no trauma or pain in lower extrem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 90 4  شماره 

صفحات  -

تاریخ انتشار 2001