A novelty digital algorithm for online measurement of dielectric loss factor of electronic transformers
نویسندگان
چکیده
There are many inherent performance limitations using traditional algorithms for online measurement of dielectric loss factor including synchronous sampling, no interharmonics and power system frequency must be invariable. In a non-stationary signal environment where power frequency fluctuation and interharmonic components exist, there is no guarantee of measurement accuracy by using traditional methods. The paper proposed a highaccuracy digital algorithm for online measurement of dielectric loss factor of electronic transformers. Theoretical basis of the new algorithm is based on a new data processing procedure including data truncation and data addition which compensates phase distortion as a result of the spectrum of addition data contains offsets. The algorithm can accurately extract the fundamental signal and calculate dielectric loss factor. Measured results from simulations and practical engineering projects show that the new algorithm has good application feasibility without being affected by the limitations rendered above. Crown Copyright 2012 Published by Elsevier Ltd. All rights reserved.
منابع مشابه
Estimation of Moisture in Transformer Insulation Using Dielectric Frequency Response Analysis by Heuristic Algorithms
Transformers are one of the most valuable assets of power systems. Maintenance and condition assessment of transformers has become one of the concerns of researchers due to huge number of transformers has been approached to the end of their lifetimes. Transformer’s lifetime depends on the life of its insulation and the insulation’s life is strongly influenced by its moisture attraction as well....
متن کاملمعرفی روش تطبیقی اصلاح شده برای اندازهگیری دقیق ولتاژ در مبدل ولتاژ نوری
There are fewer problems encountered with optical voltage transducers in comparison with their inductive and capacitive counterparts. Although capacitive and inductive transformers are used vastly for the purpose of measurement and protection in the networks, they cause problems such as core saturation and improper transient responses which decrease the accuracy of measurement and eficiency of ...
متن کاملمعرفی و شبیه سازی روش جدید اندازه گیری ضریب تلفات عایقی و پرمتیویته نسبی
For evaluating quality of electrical insulation, it is necessary to measure the property of insulators. Dielectric constant and loss tangent (tans) are two important parameters for determining the property of insulator. The measurement of above parameters is normally based on the time- domain and frequency-domain, which is costly and time consuming. In this study a multiple-frequency binary se...
متن کاملModeling the Frequency Response Movements in Power Transformers for Predicting Purposes
Power transformers are key components in electrical power supplies and their failure could cause severe consequences on continuity of service and also generates substantial costs. Identifying problems at an early stage, before catastrophic failure occurs, is a great benefit for reliable operation of power transformers. Frequency Response Analysis (FRA) is a new, well-known and powerful diagnost...
متن کاملMeasurement Error Estimation for Capacitive Voltage Transformer by Insulation Parameters
Measurement errors of a capacitive voltage transformer (CVT) are relevant to its equivalent parameters for which its capacitive divider contributes the most. In daily operation, dielectric aging, moisture, dielectric breakdown, etc., it will exert mixing effects on a capacitive divider’s insulation characteristics, leading to fluctuation in equivalent parameters which result in the measurement ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -