Novel ICD Programming and Inappropriate ICD Therapy in CRT-D Versus ICD Patients: A MADIT-RIT Sub-Study.

نویسندگان

  • Valentina Kutyifa
  • James P Daubert
  • Claudio Schuger
  • Ilan Goldenberg
  • Helmut Klein
  • Mehmet K Aktas
  • Scott McNitt
  • Martin Stockburger
  • Bela Merkely
  • Wojciech Zareba
  • Arthur J Moss
چکیده

BACKGROUND The Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate therapy (MADIT-RIT) trial showed a significant reduction in inappropriate implantable cardioverter defibrillator (ICD) therapy in patients programmed to high-rate cut-off (Arm B) or delayed ventricular tachycardia therapy (Arm C), compared with conventional programming (Arm A). There is limited data on the effect of cardiac resynchronization therapy with a cardioverter defibrillator (CRT-D) on the effect of ICD programming. We aimed to elucidate the effect of CRT-D on ICD programming to reduce inappropriate ICD therapy in patients implanted with CRT-D or an ICD, enrolled in MADIT-RIT. METHODS AND RESULTS The primary end point of this study was the first inappropriate ICD therapy. Secondary end points were inappropriate anti-tachycardia pacing and inappropriate ICD shock. The study enrolled 742 (49%) patients with an ICD and 757 (51%) patients with a CRT-D. Patients implanted with a CRT-D had 62% lower risk of inappropriate ICD therapy than those with an ICD only (hazard ratio [HR] =0.38, 95% confidence interval: 0.25-0.57; P<0.001). High-rate cut-off or delayed ventricular tachycardia therapy programming significantly reduced the risk of inappropriate ICD therapy compared with conventional ICD programming in ICD (HR=0.14 [B versus A]; HR=0.21 [C versus A]) and CRT-D patients (HR=0.15 [B versus A]; HR=0.23 [C versus A]; P<0.001 for all). There was a significant reduction in inappropriate anti-tachycardia pacings in both group and a significant reduction in inappropriate ICD shock in CRT-D patients. CONCLUSIONS Patients implanted with a CRT-D have lower risk of inappropriate ICD therapy than those with an ICD. Innovative ICD programming significantly reduces the risk of inappropriate ICD therapy in both ICD and CRT-D patients. CLINICAL TRIAL REGISTRATION http://clinicaltrials.gov; Unique identifier: NCT00947310.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mortality reduction in relation to implantable cardioverter defibrillator programming in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT).

BACKGROUND The benefit of novel implantable cardioverter defibrillator (ICD) programming in reducing inappropriate ICD therapy and mortality was demonstrated in Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT). However, the cause of mortality reduction remains incompletely evaluated. We aimed to identify factors associated with mortality, with focu...

متن کامل

Association between myocardial substrate, implantable cardioverter defibrillator shocks and mortality in MADIT-CRT.

OBJECTIVE The aim of the present study was to assess a possible association between myocardial substrate, implantable cardioverter defibrillator (ICD) shocks, and subsequent mortality. METHODS Within the multicentre automatic defibrillator implantation trial-cardiac resynchronization therapy (MADIT-CRT) population (n = 1790), we investigated the association between myocardial substrate, ICD s...

متن کامل

Reverse remodeling and the risk of ventricular tachyarrhythmias in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy).

OBJECTIVES We aimed to evaluate the relationship between echocardiographic response to cardiac resynchronization therapy (CRT) and the risk of subsequent ventricular tachyarrhythmias (VTAs). BACKGROUND Current data regarding the effect of CRT on the risk of VTA are limited and conflicting. METHODS The risk of a first appropriate implantable cardioverter-defibrillator (ICD) therapy for VTA (...

متن کامل

Reduction in inappropriate therapy and mortality through ICD programming.

BACKGROUND The implantable cardioverter-defibrillator (ICD) is highly effective in reducing mortality among patients at risk for fatal arrhythmias, but inappropriate ICD activations are frequent, with potential adverse effects. METHODS We randomly assigned 1500 patients with a primary-prevention indication to receive an ICD with one of three programming configurations. The primary objective w...

متن کامل

Heart Failure Effect of Cardiac Resynchronization Therapy on Reverse Remodeling and Relation to Outcome Multicenter Automatic Defibrillator Implantation Trial: Cardiac Resynchronization Therapy

Background—Cardiac resynchronization therapy (CRT) plus implantation of an implantable cardioverter defibrillator (ICD) reduced the risk of death or heart failure event in patients with mildly symptomatic heart failure, left ventricular dysfunction, and wide QRS complex compared with an ICD only. We assessed echocardiographic changes in patients enrolled in the MADIT-CRT trial (Multicenter Auto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 2016