Extraction and determination of chloroform in rat blood and tissues by gas chromatography-electron-capture detection: distribution of chloroform in the animal body.

نویسندگان

  • C R Vogt
  • J C Liao
  • A Y Sun
چکیده

We have developed a simple, sensitive, and accurate method for the determination of chloroform in rat blood, brain, kidney, liver, and fat. The detection limit is 2.5 ng of chloroform per gram of tissue. Studies of in vivo distribution of chloroform in rat blood and target tissues after intragastric intubation of chloroform/water show that the amount of chloroform accumulated in the different tissues increases with increasing doses. Fat tissue contains the greatest amount of chloroform. The accumulation of chloroform in rat blood and target tissues seems to be maximum 1.5 h after administration, and the apparent chloroform concentration is almost at baseline value 8 h later.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection

Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1....

متن کامل

Selective Determination of Trace-Bismuth by Extraction-Differential Pulse Polarography in Non-Aqueous Media

The voltammetric characteristics of bismuth(III)-oxinate in chloroform at the mercury electrode were investigated and a quasi-reversible behavior for Bi(III) oxinate reduction was confirmed. Preceded by the extraction of Bi(III) oxinate in chloroform, differential pulse polarography was developed in the extracts for determination of the trace-bismuth. The linear range of the calibration gra...

متن کامل

Validation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS

Dispersive liquid liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL chloroform) and disperser solvent (1000 µL acetone) were quickly injected into the water sample (...

متن کامل

Validation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS

Dispersive liquid liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL chloroform) and disperser solvent (1000 µL acetone) were quickly injected into the water sample (...

متن کامل

Extractive Differential Pulse Polarography of Mo (VI) Oxinate in Chloroform and its Application in the Determination of Molybdenum in Steel

The voltammetric characteristics of Mo (VI) oxinate at the mercury electrode, in the presence of tri-butylammonium perchlorate (tri-BAP) and piperidinium perchlorate (PP) + piperidine (P) as  two different types supporting electrolytes, have been studied in chloroform. With the both supporting electrolytes a two electron irreversible process for the reduction  of Mo (VI) oxinate was observe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 1980