Comparison of the contractile responses to irregular and regular trains of stimuli during microstimulation of single human motor axons.

نویسندگان

  • Michael Leitch
  • Vaughan G Macefield
چکیده

During voluntary contractions, human motoneurons discharge with a physiological variability of ∼20%. However, studies that have measured the contractile responses to microstimulation of single motor axons have used regular trains of stimuli with no variability. We tested the hypothesis that irregular (physiological) trains of stimuli produce greater contractile responses than regular (nonphysiological) trains of identical mean frequency but zero variability. High-impedance tungsten microelectrodes were inserted into the common peroneal nerve and guided into fascicles supplying a toe extensor muscle. Selective microstimulation was achieved for 14 single motor axons. Contractile responses were measured via an angular displacement transducer over the relevant toe. After the responses to regular trains of 10 stimuli extending from 2 to 100 Hz were recorded, irregular trains of 10 stimuli, based on the interspike intervals recorded from single motor units during voluntary contractions, were delivered. Finally, the stimulation sequences were repeated following a 2-min period of continuous stimulation at 10 Hz to induce muscle fatigue. Regular trains of stimuli generated a sigmoidal increase in displacement with frequency, whereas irregular trains, emulating the firing of volitionally driven motoneurons, displayed significantly greater responses over the same frequency range (8-24 Hz). This was maintained even in the presence of fatigue. We conclude that physiological discharge variability, which incorporates short and long interspike intervals, offers an advantage to the neuromuscular system by allowing motor units to operate on a higher level of the contraction-frequency curve and taking advantage of catch-like properties in skeletal muscle.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microstimulation of single human motor axons in the toe extensors: force production during long‐lasting trains of irregular and regular stimuli

Human motoneurones are known to discharge with a physiological variability of ~25% during voluntary contractions. Using microstimulation of single human motor axons, we have previously shown that delivering brief trains (10 pulses) of irregular stimuli, which incorporate discharge variability, generates greater contractile responses than trains of regular stimuli with identical mean frequency b...

متن کامل

Comparison of contractile responses of single human motor units in the toe extensors during unloaded and loaded isotonic and isometric conditions.

Much of the repertoire of muscle function performed in everyday life involves isotonic dynamic movements, either with or without an additional load, yet most studies of single motor units measure isometric forces. To assess the effects of muscle load on the contractile response, we measured the contractile properties of single motor units supplying the toe extensors, assessed by intraneural mic...

متن کامل

The effect of pinna reflex and dynamic stretch on spike discharge of single ?-axons and spindle afferents in caudal muscle spindles in rat

The ?-axons supplying muscle spindle (MS) induce a particular pattern of activity in spindle Ia and II afferents on contraction. From a dynamic viewpoint, the Ia shows increasing spike rates, but II-afferents do not show any activity. For evaluation of nerve fiber activity, spike amplitude (SA) is suggested to measure it as well as its benefit of diagnosing clinical symptoms. This paper aims to...

متن کامل

The effect of pinna reflex and dynamic stretch on spike discharge of single ?-axons and spindle afferents in caudal muscle spindles in rat

The ?-axons supplying muscle spindle (MS) induce a particular pattern of activity in spindle Ia and II afferents on contraction. From a dynamic viewpoint, the Ia shows increasing spike rates, but II-afferents do not show any activity. For evaluation of nerve fiber activity, spike amplitude (SA) is suggested to measure it as well as its benefit of diagnosing clinical symptoms. This paper aims to...

متن کامل

Effects of red nucleus microstimulation on the locomotor pattern and timing in the intact cat: a comparison with the motor cortex.

Effects of red nucleus microstimulation on the locomotor pattern and timing in the intact cat: a comparison with the motor cortex. To determine the extent to which the rubrospinal tract is capable of modifying locomotion in the intact cat, we applied microstimulation (cathodal current, 330 Hz; pulse duration 0.2 ms; maximal current, 25 microA) to the red nucleus during locomotion. The stimuli w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of neurophysiology

دوره 111 7  شماره 

صفحات  -

تاریخ انتشار 2014