Construction of Voxel-type Phantom Based on Computed Tomographic Data of RANDO Phantom for the Monte Carlo Simulations

نویسندگان

  • K. Minami
  • K. Ejiri
  • M. Shimo
  • M. Kato
  • Y. Takeuchi
  • K. Yonemochi
  • H. Toyama
  • K. Katada
چکیده

The Monte Carlo simulations using the mathematical phantom of a human body model is useful as a method of getting to know the details of the radiation exposure in a human body. However, it is very difficult to evaluate experimentally the validity of the calculation result of the simulation using the human body model. Then, the mathematical phantom of voxel-type (voxel phantom) for the Monte Carlo simulations was constructed from Computed Tomographic (CT) data of this phantom using a human body phantom which can actually be measured. The Alderson RANDO phantom RAN-100 type (female model) made by The Phantom Laboratories, Inc. was selected as the target of this study. Electron Gamma Shower version 4 (EGS4) which is the Monte Carlo transport code was used for the simulation of the radiation dose distribution. Some kinds of voxel phantoms with different voxel size were created, and the radiation dose distribution obtained in the simulation was considered about capability expressed finely. Moreover, 4MV X-ray is directly irradiated from the outside at the RANDO phantom, the simulation result in the same conditions as an actual measurement is compared. The fluorescence glass dosimeter (Dose Ace made by Asahi Technoglass corp.) was used for dose evaluation by the measurement. The dose distribution of the voxel phantom by EGS4 simulation expressed more detailed dose distribution structure as voxel size became fine. In comparison of the measured value and the calculated value, it differed 12 % at the maximum. The meaning which builds a voxel phantom from a RANDO phantom with the structure more near a human body is very effective in order to bury the gap of an actual measurement and a simulation, and in order to evaluate the accuracy of the human body model building method, it offers many information.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation

Background:  This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation.  Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...

متن کامل

Conventional Voxel in Tomographic Reconstruction Based upon Plane-Integral Projections – Use It or Lose It?

Introduction: While the necessity of replacing voxels with blobs in conventional tomographic reconstruction based upon line-integrals is clear, it is not however well-investigated in plane- integral-based reconstruction. The problem is more challenging in convergent-plane projection reconstruction. In this work, we are aiming at utilizing blobs as alternative to voxels. <stron...

متن کامل

Evaluation of Electron Specific Absorbed Fractions in Organs of Digimouse Voxel Phantom Using Monte Carlo Simulation Code FLUKA

Background: For preclinical evaluations of radiopharmaceuticals, most studies are carried out on mice. Values of electron specific absorbed fractions (SAF) have had vital role in the assessment of absorbed dose. In past studies, electron specific absorbed fractions were given for limited source target pairs using older reports of human organ compositions.Objective: Electron specific absorbed fr...

متن کامل

Estimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation Code FLUKA

Background: Most preclinical studies are carried out on mice. For internal dose assessment of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies, SAF values are estimated using older standard human organ compositions and values for limited source target pairs.Objective: SAF values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 keV...

متن کامل

Simulation of a Quality Control Jaszczak Phantom with SIMIND Monte Carlo and Adding the Phantom as an Accessory to the Program

Introduction Quality control is an important phenomenon in nuclear medicine imaging. A Jaszczak SPECT Phantom provides consistent performance information for any SPECT or PET system. This article describes the simulation of a Jaszczak phantom and creating an executable phantom file for comparing assessment of SPECT cameras using SIMIND Monte Carlo simulation program which is well-established fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004