Efficacy of cardiac resynchronization therapy in very old patients: the Insync/Insync ICD Italian Registry.

نویسندگان

  • Augusto Achilli
  • Federico Turreni
  • Maurizio Gasparini
  • Maurizio Lunati
  • Massimo Sassara
  • Massimo Santini
  • Maurizio Landolina
  • Luigi Padeletti
  • Andrea Puglisi
  • Mario Bocchiardo
  • Serafino Orazi
  • Giovanni Battista Perego
  • Sergio Valsecchi
  • Alessandra Denaro
چکیده

AIMS To assess the effects of cardiac resynchronization therapy (CRT) in > or =80-year-old patients vs. patients <80 years, in terms of clinical, functional, and echocardiographic parameters after 12 month of CRT, survival, and incidence of arrhythmic events. METHODS AND RESULTS The study population consisted of 1181 CRT patients (85 were > or =80 years old). They were enrolled in a national observational registry and underwent baseline evaluation and periodical follow-up visits. In the overall population, New York Heart Association class and ejection fraction (EF) improved and ventricular diameters decreased. Similar changes were observed in the two groups. In the study population, 157 patients died, 144 (13%) in the <80 years group and 13 (15%) in the > or =80 years group. There was a higher all-cause mortality (log-rank test, P = 0.015) among > or =80 years patients, with a trend towards higher sudden cardiac death (SCD) (P = 0.057), but similar non-SCD (P = 0.293). Using the combined endpoint of SCD or appropriate shock from a defibrillator for ventricular fibrillation, no significant differences resulted between groups (P = 0.455). In both groups, lower EF was associated with higher mortality. CONCLUSION Cardiac resynchronization therapy demonstrated similar efficacy in patients aged > or =80 years and in those under 80, in terms of clinical and functional parameters and reverse remodelling. Similarly, CRT resulted in comparable effects on death for heart failure and on SCD.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safety of transvenous cardiac resynchronization system implantation in patients with chronic heart failure: combined results of over 2,000 patients from a multicenter study program.

OBJECTIVES The purpose of this study was to evaluate the safety of implanting a cardiac resynchronization therapy (CRT) system. BACKGROUND Clinicians and patients require data on the safety of the CRT implant procedure to estimate procedural risk. METHODS We evaluated outcomes of transvenous CRT system implantation in 2,078 patients from the Multicenter InSync Randomized Clinical Evaluation...

متن کامل

Effectiveness of cardiac resynchronization therapy in heart failure patients with valvular heart disease: comparison with patients affected by ischaemic heart disease or dilated cardiomyopathy. The InSync/InSync ICD Italian Registry

AIMS To analyse the effectiveness of cardiac resynchronization therapy (CRT) in patients with valvular heart disease (a subset not specifically investigated in randomized controlled trials) in comparison with ischaemic heart disease or dilated cardiomyopathy patients. METHODS AND RESULTS Patients enrolled in a national registry were evaluated during a median follow-up of 16 months after CRT i...

متن کامل

Cardiac resynchronization with sequential biventricular pacing for the treatment of moderate-to-severe heart failure.

OBJECTIVES The InSync III study evaluated sequential cardiac resynchronization therapy (CRT) in patients with moderate-to-severe heart failure and prolonged QRS. BACKGROUND Simultaneous CRT improves hemodynamic and clinical performance in patients with moderate-to-severe heart failure (HF) and a wide QRS. Recent evidence suggests that sequentially stimulating the ventricles might provide addi...

متن کامل

Antiarrhythmic effect of reverse ventricular remodeling induced by cardiac resynchronization therapy: the InSync ICD (Implantable Cardioverter-Defibrillator) Italian Registry.

OBJECTIVES We investigated whether the reverse remodeling after cardiac resynchronization therapy (CRT) might reduce the occurrence of ventricular arrhythmias (VAs). BACKGROUND It is currently debated whether CRT has an effect on the burden of VAs. METHODS The study included 398 patients treated with a CRT defibrillator and with a follow-up of at least 12 months. Spontaneous VAs detected by...

متن کامل

Sustained reverse left ventricular structural remodeling with cardiac resynchronization at one year is a function of etiology: quantitative Doppler echocardiographic evidence from the Multicenter InSync Randomized Clinical Evaluation (MIRACLE).

BACKGROUND Cardiac resynchronization therapy (CRT) is an effective therapy for patients with moderate to severe heart failure and prolonged QRS duration. The purpose of this study was to determine whether reverse left ventricular (LV) remodeling and symptomatic benefit from CRT were sustained at 12 months, and if so, in what proportion of patients this occurred. METHODS AND RESULTS Serial Dop...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 9 9  شماره 

صفحات  -

تاریخ انتشار 2007